Manualsbrain.com
ja
English
Deutsch
Español
Français
Italiano
Português
Русский
조선말, 한국어
中文
マニュアル
ブランド
Mitsubishi Electronics
FR-F740P
ユーザーズマニュアル
Mitsubishi Electronics FR-F740P ユーザーズマニュアル
ダウンロード
いいね
全画面
標準
ページ
/
410
移動
74
Parameters according to purposes
4.3
IPM motor control <IPM>
77
4.3.1
Setting procedure of IPM motor control <IPM> ........................................................................................................ 77
4.3.2
Initializing the parameters required to drive an IPM motor (Pr.998) <IPM> ............................................................ 80
4.3.3
IPM motor test operation (Pr.800) <IPM>................................................................................................................. 82
4.3.4
Adjusting the speed control gain (Pr.820, Pr.821) <IPM>........................................................................................ 84
4.4
Adjustment of the output torque (current) of the motor
87
4.4.1
Manual torque boost (Pr. 0, Pr. 46) <V/F>................................................................................................................ 87
4.4.2
Simple magnetic flux vector control (Pr.80, Pr.90) <S MFVC>................................................................................ 89
4.4.3
Slip compensation (Pr. 245 to Pr. 247) <V/F><S MFVC> ....................................................................................... 90
4.4.4
Stall prevention operation
(Pr. 22, Pr. 23, Pr. 48, Pr. 49, Pr. 66, Pr. 148, Pr. 149, Pr. 154, Pr. 156, Pr. 157) .................................................. 91
4.5
Limiting the output frequency
96
4.5.1
Maximum/minimum frequency (Pr. 1, Pr. 2, Pr. 18) ................................................................................................. 96
4.5.2
Avoiding mechanical resonance points (Frequency jump) (Pr. 31 to Pr. 36).......................................................... 97
4.6
V/F pattern
98
4.6.1
Base frequency, voltage (Pr. 3, Pr. 19, Pr. 47) <V/F><S MFVC> ........................................................................... 98
4.6.2
Load pattern selection (Pr. 14) <V/F> ..................................................................................................................... 100
4.6.3
Adjustable 5 points V/F (Pr. 71, Pr. 100 to Pr. 109) <V/F> .................................................................................... 101
4.7
Frequency setting by external terminals
102
4.7.1
Multi-speed setting operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239) ................................................ 102
4.7.2
Jog operation (Pr. 15, Pr. 16)................................................................................................................................... 104
4.7.3
Input compensation of multi-speed and remote setting (Pr. 28) ............................................................................ 106
4.7.4
Remote setting function (Pr. 59).............................................................................................................................. 106
4.8
Setting of acceleration/deceleration time and
acceleration/deceleration pattern
109
4.8.1
Setting of the acceleration and deceleration time (Pr.7, Pr.8, Pr.20, Pr.21,
Pr.44, Pr.45, Pr.147, Pr.791, Pr.792)....................................................................................................................... 109
4.8.2
Starting frequency and start-time hold function (Pr.13, Pr.571) <V/F><S MFVC>............................................... 113
4.8.3
Minimum motor rotation frequency (Pr.13) <IPM> ................................................................................................. 114
4.8.4
Acceleration/deceleration pattern (Pr.29, Pr.140 to Pr.143)................................................................................... 115
4.9
Selection and protection of a motor
117
4.9.1
Motor protection from overheat (Electronic thermal relay function) (Pr. 9, Pr. 51)................................................ 117
4.9.2
Applied motor (Pr. 71) .............................................................................................................................................. 122
4.10 Motor brake and stop operation
123
4.10.1
DC injection brake of general-purpose motor control (Pr. 10 to Pr. 12) <V/F><S MFVC>................................... 123
4.10.2
DC injection brake of IPM motor control (Pr.10, Pr.11) <IPM>.............................................................................. 124
4.10.3
Selection of a regenerative brake and DC feeding (Pr. 30, Pr. 70)........................................................................ 125
4.10.4
Stop selection (Pr. 250)............................................................................................................................................ 130
4.10.5
Output stop function (Pr.522)................................................................................................................................... 131
4.11 Function assignment of external terminal and control
133
4.11.1
Input terminal function selection (Pr. 178 to Pr. 189).............................................................................................. 133
4.11.2
Inverter output shutoff signal (MRS signal, Pr. 17) ................................................................................................. 136
4.11.3
Condition selection of function validity by the second function selection signal (RT)
(RT signal, Pr. 155)................................................................................................................................................... 137
4.11.4
Start signal selection (STF, STR, STOP signal, Pr. 250)....................................................................................... 138
4.11.5
Output terminal function selection (Pr. 190 to Pr. 196)........................................................................................... 140
4.11.6
Detection of output frequency (SU, FU, FU2 signal, Pr. 41 to Pr. 43, Pr. 50,
Pr. 870)...................................................................................................................................................................... 144
4.11.7
Output current detection function
(Y12 signal, Y13 signal, Pr. 150 to Pr. 153, Pr. 166, Pr. 167)................................................................................ 146
4.11.8
Remote output function (REM signal, Pr. 495 to Pr. 497) ...................................................................................... 148
4.11.9
Pulse train output of output power (Y79 signal, Pr. 799)........................................................................................ 149
4.12 Monitor display and monitor output signal
150
4.12.1
Speed display and speed setting (Pr. 37, Pr. 144, Pr. 505) ................................................................................... 150
4.12.2
DU/PU monitor display selection
(Pr. 52, Pr. 54, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)........................................................ 152
4.12.3
FM, AM terminal function selection (Pr.55, Pr.56, Pr.867)..................................................................................... 157
4.12.4
Terminal FM, AM calibration
(Calibration parameter C0 (Pr. 900), C1 (Pr. 901))................................................................................................. 159
前へ
次へ
1
…
83
84
85
86
87
…
410