9 Specifications 
This chapter provides the power requirements, operating conditions (environmental requirements), physical 
requirements, hardware specifications, and video resolutions of the HP Server tc3100.  
The following tables provide the specifications required for normal operation of the HP Server tc3100. 
NOTE 
The specifications and requirements for the power supply and environment can vary if 
you install a mass storage device in the server that has more stringent environmental limits 
than required for the HP Server. Ensure the operating environment for any mass storage 
devices you intend to install are compatible with the server environmental requirements. 
Power Supply Requirements 
Parameter Characteristics 
Input Type 
Wide-ranging, PFC 
Input Voltage  
100 to 127 VAC ± 10%, 50/60 Hz  
200 to 240 VAC ± 10%, 50/60 Hz 
Operating Current 
100 VAC: 
3.49 A, 345 W 
120 VAC: 
2.69 A, 339 W 
200/208 VAC:  1.80 A, 329 W 
220/230 VAC:  1.56 A, 325 W 
In-rush Current 
50 A peak, 240 VAC 
Operating Power 
320 W Continuous 
Environment 
 
Parameter Conditions 
Temperature 
Operating 
Non-operating 
 
5
° to 35° C (41° to 95° F)  
-40° to +65° C (-40° to +149° F) 
Humidity  
Operating 
 
Non-operating 
 
20% to 80% relative humidity,  
non-condensing  
5% to 95% relative humidity, 
non-condensing 
Altitude 
Operating 
Non-operating 
 
-30 to 3,000 m (~ 10,000 ft) 
-30 to 12,000 m (~ 40,000 ft) 
Thermal Output 
Maximum Operating 
 
1662 BTU/hr 
Acoustic Emissions 
Sound level (LpA): <40 dB(A)