DELL 7.4 ユーザーズマニュアル

ページ / 232
Event ID — 2199
Description
The virtual disk cache policy has changed.
Severity
Informational
Cause and 
Action
Cause: User has provided invalid input for the chosen operation.
Action: None
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1201
Event ID — 2200
Description
Replace Member Operation not possible as SAS/SATA is not supported in the same 
virtual disk.
Severity
Warning/ Non-critical
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
903
Event ID — 2201
Description
A global hot spare failed.
Severity
Warning/ Non-critical
Cause and 
Action
Cause: The controller is not able to communicate with a disk that is assigned as a 
dedicated hot spare. The disk may have been removed. There may also be a bad or 
loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the 
cables. If necessary, replace the disk and reassign the hot spare.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2070
108