Belkin 8000I ユーザーズマニュアル

ページ / 88
 
 
41
Northstar 8000i System - 12" Display Processor Installation Manual 
 
8.3 
Utility Port 
Connect to other electronic devices using the the optional Northstar 8000i Utility cable 
(NS004801). The Utility cable has the following communication capabilities. 
• 
1 x NMEA Receive (see "NMEA" page 44) 
• 
1 x NMEA Transmit
 
• 
External Alarm (see "External Alarm" page 46) 
• 
Remote Power On 
• 
External Wake Up (see "External Alarm" page 46) 
• 
System Controller re program (Service only) 
 
NS004801 Utility Cable  
 
Utility connector Pinout viewed looking at connector 
 
Pin
 
Color
 
Signal
 
3 Yellow 
NMEA 
RX 
6 Black/White 
NMEA 
RX 
White 
NMEA TX + 
Black 
NMEA TX - (Ground) 
Orange 
NavBus + (Future) 
Blue 
NavBus - (Future) 
Dark Green 
External Alarm 
11 
Gray 
External Wake Up  
12 
Light Green 
Remote Power On 
Purple 
System Controller (re program TX Service Only) 
Pink 
System Controller (re program  RX Service Only) 
10 
Brown/White 
System Controller (reset Service Only) 
 
 
8.3.1 
External Wake Up and Remote Power On 
External Wake Up sends a signal to another device to initiate Power On. Connect External 
Wake  to the Remote Power On of the other device. 
The External Wake Up feature of the 8000i provides the ability for an 8000i Device to control 
the power state of another 8000i device that it is attached to.