Setup Mode Details 
48
3A0869J
Maintenance 1-3 (Screens 24-26)
Maintenance 1 (Screen 24) displays if 
 is selected 
on Setup Home (Screen 17). The Maintenance Screens 
display actual and target maintenance timers for meters 
and solvent valves (Maintenance 1, Screen 24), dose 
valves (Maintenance 2, Screen 25), and fluid filters and 
air filters (Maintenance 3, Screen 26). Timers for meters 
are settable from 0 to 2,000,000 L or 0 to 528,344 gal-
lons. Timers for valves are settable from 0 to 9,999,999 
counts. Timers for filters are settable from 0 to 9999 
days.
Press 
 to move through the three mainte-
nance screens.
Press 
 to clear the maintenance total that is 
highlighted. A confirmation screen appears. Use 
to highlight and press 
on the   to clear 
the batch totals. No other button press will clear the 
totals. Press 
 on the   to return to the active 
Maintenance Screen without clearing.
Maintenance Recommendations
The following table shows recommended starting values 
for maintenance. Maintenance needs will vary based on 
individual applications and material differences.
F
IG
. 45. Setup Maintenance 1-3 (Screens 24-26)
Maintenance
actual and
target
Meters
Solvent valves
Home
Fluid Filters
Air filter
Maintenance 1
Maintenance 2
Maintenance 3
Dose
valves
Days
Clear totals
Component
Recommended Maintenance 
Frequency
Solvent Valves
1,000,000 cycles
Fluid Filter
5 days,
daily check is recommended
Air Filter
30 days
Pumps
250,000 cycles
Dose Valves
1,000,000 cycles
Meters
5,000 gallons