Graco 3A0869J ユーザーズマニュアル

ページ / 80
Dynamic Dosing Restrictor Selection Graphs
3A0869J
65
Dynamic Dosing Restrictor Selection Graphs
Use the graphs on pages 66- 70 as a guide to determine 
the correct restrictor size for your desired flow and mate-
rial viscosity. Table 6 lists the available restrictor sizes.
Example: 
Application: air spray system with a 5:1 mix ratio
Fluid Supply: 1:1 pumps at 100 psi (7 bar, 0.7 MPa) 
Flow Rate: 300 cc/min at the gun
Select the Restrictor Size: choose either the 0.040 
or 0.070 orifice, to ensure that the pressure differen-
tial is not more than 10-20 psi (0.7-1.4 bar, 
0.07-0.14 MPa), provided the fluid viscosities are 
similar to those tested.
If the viscosity of component B is lower than the vis-
cosity of the chart used for selection you may need 
to use a smaller restrictor or decrease the pressure 
differential.
If the viscosity of component B is higher than the 
viscosity of the chart used for selection you may 
need to use a larger restrictor or increase the pres-
sure differential.
In systems using an air-assisted gun, if the fluid 
pressure of component A is higher than the compo-
nent A pressure from the charts you may need to 
use a larger restrictor or increase the pressure dif-
ferential.
* These restrictors are included in Injection Kit 
15U955.
These restrictors are optional sizes, not included in 
the Injection Kit.
Table 6: Restrictor Sizes
Size Code
Orifice Size
Part No.
2*
0.020
15U936
3*
0.030
15U937
4*
0.040
15U938
5
0.050
15U939
6
0.060
15U940
7*
0.070
15U941
8
0.080
16D554