Furuno CH-250 ユーザーズマニュアル

ページ / 79
 
32 
 
 
Table 3-1 general checks (con’t) 
Check Item 
Check point, Rating 
Wiring check 
• 
All cables are correctly connected. 
• 
All lead wires are tightly fixed with contact 
pins or crimp-on lugs. 
• 
All screws are firmly fastened. 
• 
Cables are firmly secured. 
• 
Cables shields are properly grounded. 
Rejecting source of noise and 
interference 
• 
Noise generating machinery (motor, 
radiotelephone, TV set, etc.) are not placed 
nearby. 
• 
Magnetic devices are not placed in the 
vicinity of display unit. 
Earth 
• 
Each unit is grounded with a copper strap. 
Ship’s mains voltage 
• 
Ship’s mains voltage is stable 12, 24 or 32 
VDC. 
Watertightness 
• 
Water should not leak from the main body 
flange or along the main shaft. 
3.2 
TX Frequency Checking 
Check the TX frequency after the installation. 
1.  Press the [MENU] key to open the user menu. 
2.  Press the cursor pad to select SYS at the top of the menu display. 
NO
YES
: SELECT
: CHANGE
MENU: END
MENU
COM1
COM2 HORZ VERT    ES     SHORT-CUT
SYS
GO TO SYS MENU
 
User menu (SYS) 
3.  Press the [] to select GO TO SYS MENU. 
4.  Press the [] to select YES to display the system menu.