EMERGENCIES
: 
If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department. 
Emergencies 
Possible Cause 
Prevention / Solution 
Gas leaking from 
cracked/cut /burned 
hose. 
 
 
 
Gas leaking from LP 
cylinder. 
 
Gas leaking from LP 
cylinder valve. 
 
Gas leaking between 
LP cylinder and 
regulator connection. 
 
Fire coming through 
control panel. 
 
 
 
Grease fire or 
continuous excessive 
flames above 
cooking surface. 
 
Damaged hose. 
 
 
 
 
 
 
Mechanical failure due to 
rusting or mishandling. 
 
 
Failure of cylinder valve from 
mishandling or mechanical 
failure. 
 
Improper installation, 
connection not tight, failure of 
rubber seal. 
 
 
Fire in burner tube section of 
burner due to blockage. 
 
 
 
 
Too much grease building in 
burner area. 
 
Turn off gas at LP cylinder or at source on natural gas 
systems. If anything but burned, replace 
valve/hose/regulator. If burned, discontinue use of 
product until a plumber has investigated cause and 
corrections are made. 
 
 
Replace LP cylinder. 
 
 
 
Turn off LP cylinder valve. Return LP cylinder to gas 
supplier. 
 
 
Turn off LP cylinder valve. Remove regulator from 
cylinder and visually inspect rubber seal for damage. 
See LP cylinder Leak Test and Connecting Regulator to 
the LP Cylinder. 
 
Turn off control knobs and LP cylinder valve. Leave lid 
open to allow flames to die down. After fire is out and 
grill is cold, remove burner and inspect for spider nests 
or rust. See Natural Hazard and Cleaning the Burner 
Assembly pages. 
 
Turn off control knobs and LP cylinder valve. Leave lid 
open to allow flames to die down. After cooling, clean 
food particles and excess grease from inside firebox 
area, grease tray, and other surfaces. 
TROUBLESHOOTING:   
Problem 
Possible Case 
Prevention / Solution 
 
Burner(s) will not light 
ignitor. 
 
Continued on next 
page. 
GAS ISSUES: 
 
Trying to light wrong burner. 
 
 
Burner not engaged with 
control valve. 
 
 
Obstruction in burner. 
 
 
 
No gas flow. 
 
 
Vapor lock at coupling nut to 
LP cylinder. 
 
Coupling nut LP cylinder valve 
not fully connected
 
ELECTRICAL ISSUE 
 
Electrode cracked or broken or 
sparks somewhere other than 
tip. 
 
 
Electrode tip not in proper 
position.
 
 
 
See instructions on control panel and in Use and Care 
section. 
 
Make sure valves are positioned inside of burner tubes. 
 
 
 
Ensure burner tubes are not obstructed with spider webs 
or other matter. See cleaning section of Use and Care. 
 
 
Make sure LP cylinder is not empty. If LP cylinder is not 
empty, refer to “Sudden drop in gas flow”. 
 
Turn off knobs and disconnect coupling nut from LP 
cylinder. Reconnect and retry. 
 
Turn the coupling nut approximately one-half to 
three-quarters additional turn until solid stop. Tighten by 
hand only- do not use tools. 
 
 
Replace electrode(s). 
 
 
Main Burners: 
 
Tip of electrode should be pointing toward gas port 
opening on burner. The distance should be 1/8” to 3/16”. 
Adjust if necessary. 
Side Burner: 
 
Tip of electrode should be pointing toward gas port 
opening on burner. The distance should be 1/8” to 3/16”. 
Adjust if necessary.