Jenn-Air 750-0165 ユーザーズマニュアル

ページ / 34
 
 
  
 
GENERAL 
Although all gas connections on the grill are leak 
tested at the factory prior to shipment, a complete 
gas tightness check must be performed at the 
installation site. Periodically check the whole 
system for leaks following the procedures listed 
below.  
 
If the smell of gas is detected at anytime you should 
immediately check the entire system for leaks. 
 
BEFORE TESTING
 
Make sure all packing materials have been 
removed from the grill, including the burner tie-
down straps. 
 
 
 
Make a soap solution of one part liquid detergent 
and one part water. You will need a spray bottle, 
brush, or rag to apply the solution to the fittings.  
 
TO TEST 
1.  Turn off all control valves, and turn on the gas 
supply. 
 
2.  Apply the soap solution to all pipe fittings, from 
the natural gas regulator and supply valve or 
from the LP cylinder up to and including the 
pipe that connects to the burners. Soap bubbles 
will appear where a leak is present.  
 
3.  If a leak is present, immediately turn off the gas 
supply and tighten the leaky fittings.   
 
4.  Turn the gas back on and recheck.  
 
5.  If gas continues to leak from any of the fittings, 
turn off the gas supply, and contact customer 
service at 1-800-554-5799. 
 
Only those parts recommended by the 
manufacturer should be used on the grill. 
Substitutions will void the warranty.  
 
GAS FLOW CHECK 
Each grill burner is tested and adjusted at the 
factory prior to shipment. However, variations in the 
local gas supply may make it necessary to adjust 
the burners.  
 
Flames should be blue and stable with no yellow 
tips, excessive noise or lifting.  
 
If any of these conditions exist, first check to see if 
the burner is blocked by dirt, debris, spider webs, 
etc.  
  
 
It is handy to keep a spray bottle of soapy water 
near the shut-off valve of the gas supply line. Spray 
all the fittings. Bubbles indicate leaks. 
 
Disconnected liquid propane cylinders must have 
threaded valve plugs tightly installed, and must not 
be stored in a building, garage or any other 
enclosed area. 
 
 
 
 
 
 
 
 
 
The gas must be turned off at the supply cylinder 
when the unit is not in use. 
 
If the appliance is stored indoors, the cylinder must 
be disconnected and removed from the appliance. 
Cylinders must be stored outdoors in a well-
ventilated area out of the reach of children. 
   
 
 
 
 
 
 
 
 
 
 
 
WARNING    
Do not use the grill until all connections have 
been checked and do not leak.  
 
Do not smoke while leak testing.  
 
Never leak test with an open flame.  
LEAK TESTING  XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX 
 
WARNING 
Storage of an outdoor cooking gas appliance 
indoor is permissible only if the cylinder is 
disconnected and removed from the outdoor 
cooking gas appliance
 
WARNING 
Cylinder must be stored outdoors out of the reach 
of children and must not be stored in a building, 
garage or any other enclosed area. 
 