7.  Arrange with your local gas company or licensed contractor to 
have a gas supply line connected to the inlet of the stainless 
steel flex tube assembly. The gas supply must have a shutoff 
valve that is close to the post in case of emergency and must 
be shutoff when the grill is not in use. See Figure 8.
The grill and its individual shutoff valves must be disconnected 
from the gas supply piping system during any pressure testing 
of that system at test pressures in excess of 1/2 PSIG. The 
grill must be isolated from the gas supply piping system by 
closing its individual manual shutoff valves during any pres-
sure testing of the gas supply piping system at test pressures 
equal to or less than 1/2 PSIG.
WARNING: DO NOT SUPPLY LP GAS TO A GRILL DE-
SIGNED FOR NATURAL GAS OR NATURAL GAS TO A 
GRILL DESIGNED FOR LP GAS.
Gas leak tests should be completed as directed in the grill 
Owner’s Manual.
Completely fill remaining hole with soil.
24 3/4”
ABOVE GRADE
Figure 8
8.  Install the post access door and grease cup as shown in Fig-
ures 9 and 10.
Figure 9
i
n
-g
round
 p
oSt
 A
SSEmbly
STEP #1
STEP #2
STEP #3
STEP #4
NOTE: GAS LINE REMOVED FOR CLARITY
Figure 10
9.  Continue assembly as directed by the Owner’s Manual pack-
aged with the grill head.
Test for gas leaks as directed by the grill’s Owners Manual. The 
grill and its individual shutoff valves must be disconnected from 
the gas supply piping system during any pressure testing of 
that system at test pressures in excess of 1/2 PSIG. The grill 
must be isolated from the gas supply piping system by closing 
its individual manual shutoff valves during any pressure testing 
of the gas supply piping system at test pressures equal to or 
less than 1/2 PSIG. 
WARNING: DO NOT SUPPLY LP GAS TO A GRILL DE-
SIGNED FOR NATURAL GAS OR NATURAL GAS TO A GRILL 
DESIGNED FOR LP GAS.
Gas leak tests should be completed as directed in the grill 
owner’s manual.