Mitsubishi Electronics fx3u ユーザーズマニュアル

ページ / 8
Requirement for Compliance with LVD directive
The following products have shown compliance through direct
testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European
Directive for Low Voltage (2006/95/EC) when used as directed by
the appropriate documentation.
Type :
Programmable Controller (Open Type Equipment)
Models :
MELSEC FX
3U
 series manufactured
from May 1st, 2005
FX
3U
-
MR/ES(-A)
Where 
 indicates:16,32,48,64,80
from November 1st, 2005 FX
3U
-
MT/ES(-A)
FX
3U
-
MT/ESS
Where 
 indicates:16,32,48,64,80
from February 1st, 2006
FX
3U
-128MR/ES(-A)
FX
3U
-128MT/ES(-A)
FX
3U
-128MT/ESS
FX
3U
-
MR/DS
Where 
 indicates:16,32,48,64,80
from September 1st, 2010 FX
3U
-
MR/UA1
FX
3U
-
MS/ES
Where 
 indicates:32,64
Models :MELSEC FX
2N
 series manufactured
from July 1st, 1997
FX
2N
-
ER-ES/UL FX
2N
-
ET-ESS/UL
Where 
 indicates:32,48
FX
2N
-16EYR-ES/UL
from April 1st, 1998
FX
2N
-48ER-DS
from August 1st, 1998 FX
2N
-48ER-UA1/UL
from August 1st, 2005 FX
2N
-8ER-ES/UL
FX
2N
-8EYR-ES/UL
from September 1st, 2010 FX
2N
-8EYR-S-ES/UL
For the products above, PLCs manufactured
before March 31st, 2002 are compliant with IEC1010-1
from April 1st, 2002 to April 30th, 2006 are compliant with EN61131-
2:1994+A11:1996+A12:2000
after May 1st, 2006 are compliant with EN61131-2:2007
Caution for compliance with EC Directive
Installation in Enclosure
Programmable logic controllers are open-type devices that must be
installed and used within conductive control boxes. Please use the
FX3U Series programmable logic controllers while installed in
conductive shielded control boxes. Please secure the control box lid
to the control box (for conduction). Installation within a control box
greatly affects the safety of the system and aids in shielding noise
from the programmable logic controller.
Caution for Analog Products in use
The analog special adapters have been found to be compliant to the
European standards in the aforesaid manual and directive. However,
for the very best performance from what are in fact delicate
measuring and controlled output device Mitsubishi Electric would like
to make the following points;
As analog devices are sensitive by nature, their use should be
considered carefully. For users of proprietary cables (integral with
sensors or actuators), these users should follow those
manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used.
If NO other EMC protection is provided, then users may experience
temporary induced errors not exceeding +10%/-10% in very heavy
industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC
precautions are followed with general good EMC practice for the
users complete control system, users should expect normal errors
as specified in this manual.
- Sensitive analog cable should not be laid in the same trunking 
or cable conduit as high voltage cabling. Where possible users 
should run analog cables separately.
- Good cable shielding should be used. When terminating the 
shield at Earth - ensure that no earth loops are accidentally 
created.
Standard
Remark
EN61000-6-4:2007
- Generic emission 
standard
Industrial environment
EN50081-2:1993
Electromagnetic
compatibility
Compliance with all relevant aspects
of the standard.
• Emission-Enclosure port
• Emission-Low voltage AC mains
port
• Emission-Telecommunications/
network port
EN50082-2:1995
Electromagnetic
compatibility
- Generic immunity 
standard
Industrial environment
Compliance with all relevant aspects
of the standard.
• RF immunity
• Fast Transients
• ESD
• Conducted
• Power magnetic fields
EN61131-2:1994
           /A11:1996
            /A12:2000
Programmable controllers
- Equipment 
requirements and tests
Compliance with all relevant aspects
of the standard.
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• Damped oscillatory wave
EN61131-2:2007
Programmable controllers
- Equipment 
requirements and tests
Compliance with all relevant aspects
of the standard.
EMI
• Radiated Emission
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast Transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Standard
Remark
EN61131-2:2007
Programmable controllers
- Equipment 
requirements and tests
The equipment has been assessed
as a component for fitting in a
suitable enclosure which meets the
requirements of EN61131-2:2007
Standard
Remark
IEC1010-1:1990
            /A1:1992
Safety requirements for 
electrical equipment for 
measurement, control, and 
laboratory use
- General requirements
The equipment has been assessed
as a component for fitting in a
suitable enclosure which meets the
requirements of IEC 1010-1:
1990+A1:1992
EN61131-2:1994      :2007
           /A12:2000
           /A11:1996
Programmable controllers
- Equipment 
requirements and tests
The equipment has been assessed
as a component for fitting in a
suitable enclosure which meets the
requirements of EN61131-2:
1994+A11:1996+A12:2000, :2007
- When reading analog values, EMC induced errors can be 
smoothed out by averaging the readings. This can be achieved 
either through functions on the analog special adapter/block or 
through a users program in the FX
3U
 Series PLC main unit.
Associated manuals
FX
3U
 Series PLC (main unit) comes with this document (hardware
manual).
For a detailed explanation of the FX
3U
 Series hardware and
information on instructions for PLC programming and special
extension unit/block, refer to the relevant documents.
How to obtain manuals
For the necessary product manuals or documents, consult with the
Mitsubishi Electric dealer from where you purchase your product.
Incorporated Items
Check if the following product and items are included in the package:
1.
Outline
1.1
Part names 
Manual name
Manual No.
Description
FX
3U
 Series 
User's Manual 
- Hardware 
Edition
JY997D16501
MODEL CODE: 
09R516
Explains FX
3U
 Series PLC 
specification details for I/O, 
wiring, installation, and 
maintenance.
FX
3G
/FX
3U
/
FX
3UC
 Series 
Programming 
Manual 
- Basic & Applied 
Instruction Edition
JY997D16601
MODEL CODE: 
09R517
Describes PLC 
programming for basic/
applied instructions STL/
SFC programming and 
devices.
MELSEC-Q/L/F
Structured
Programming
Manual
(Fundamentals)
SH-080782
MODEL CODE: 
13JW06
Programming methods, 
specifications, functions, 
etc. required to create 
structured programs.
FXCPU
Structured
Programming
Manual
[Device & Common]
JY997D26001
MODEL CODE: 
09R925
Devices, parameters, etc. 
provided in structured 
projects of GX Works2.
FXCPU
Structured
Programming
Manual
[Basic & Applied 
Instruction]
JY997D34701
MODEL CODE: 
09R926
Sequence instructions 
provided in structured 
projects of GX Works2.
FXCPU
Structured
Programming
Manual
[Application 
Functions]
JY997D34801
MODEL CODE: 
09R927
Application functions 
provided in structured 
projects of GX Works2.
FX Series User’s 
Manual - Data 
Communication 
Edition
JY997D16901
MODEL CODE: 
09R715
Explains N:N link, parallel 
link, computer link, no 
protocol communication by 
RS instructions/FX
2N
-
232IF.
FX
3G
/FX
3U
/
FX
3UC
 Series 
User's Manual 
- Analog Control 
Edition
JY997D16701
MODEL CODE: 
09R619
Describes specifications for 
analog control and 
programming methods for 
FX
3G
/FX
3U
/FX
3UC
 Series 
PLC.
FX
3G
/FX
3U
/
FX
3UC
 Series 
User's Manual 
- Positioning 
Control Edition
JY997D16801
MODEL CODE: 
09R620
Explains the specifications 
for positioning control of 
FX
3G
/FX
3U
/FX
3UC
 Series 
and programming 
procedures
Included Items
Main units
FX
3U
-16M  to
FX
3U
-128M
Product
1 unit
Dust proof protection sheet
1 sheet
Manuals [Japanese version, 
English version]
1 manual 
each
Input/output extension units
FX
2N
-32E ,
FX
2N
-48E
Product
1 unit
Extension cable
1 cable
Input/output number label
1 sheet
Input/output extension blocks
FX
2N
-8E , 
FX
2N
-16E
Product
1 unit
Input/output number label
1 sheet
No.
Name
[1]
Top cover
[2]
Battery cover
[3]
Special adapter connecting hooks (2 places)
[4]
Expansion board dummy cover
[5]
RUN/STOP switch
[6]
Peripheral device connecting connector
[7]
DIN rail mounting hooks
[8]
Model name (abbreviation)
[9]
Input display LEDs (Red)
[10]
Terminal block covers
[11]
Extension device connecting connector cover
[12]
Operation status display LEDs
POWER
Green On while power is on the PLC.
RUN
Green On while the PLC is running.
BATT
Red
Lights when the battery voltage drops.
ERROR
Red
Flashing when a program error occurs.
Red
Lights when a CPU error occurs.
[13]
Output display LEDs (Red)
FX
3U
-48MR/ES
FX
3U
-48M
FX
3U
ERROR
RUN
BATT
POWER
R
0
3
1 2
IN
OUT
6
4 5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
0
3
1 2
6
4 5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
Y12
Y10
Y16
Y14
Y22
Y20
Y26
COM5
COM1
Y24
Y6
Y4
Y2
Y0
Y7
Y11
Y13
Y5
COM2
Y3
Y1
COM3
Y15
Y17
COM4
Y23
Y25
Y27
Y21
X5
X0
X1
X2
X3
X7
X11
X13
X4
0V
S/S
N
24V
X6
X10
X12
X14
X16
X20
L
X27
X23
X25
X15
X17
X21
X24
X26
X22
FX
3U
-48MR/ES
FX
3U
-48M
FX
3U
ERROR
RUN
BATT
POWER
R
0
3
1 2
IN
OUT
6
4 5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
0
3
1 2
6
4 5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
Y12
Y10
Y16
Y14
Y22
Y20
Y26
COM5
COM1
Y24
Y6
Y4
Y2
Y0
Y7
Y11
Y13
Y5
COM2
Y3
Y1
COM3
Y15
Y17
COM4
Y23
Y25
Y27
Y21
X5
X0
X1
X2
X3
X7
X11
X13
X4
0V
S/S
N
24V
X6
X10
X12
X14
X16
X20
L
X27
X23
X25
X15
X17
X21
X24
X26
X22
[1]
[2]
[3]
[9]
[10]
[11]
[12]
[13]
[8]
[4]
[5]
[6]
[7]