SAFETy INFORMATION
Continued
6.  Do not add extra logs or ornaments such as 
pine cones, vermiculite, or rock wool. Using 
these added items can cause sooting. Do not 
add lava rock around base. Rock and debris 
could fall into the control area of fireplace.
7.  To prevent the creation of soot, follow the 
instructions in Cleaning and Maintenance, 
page 21.
8.  Before using furniture polish, wax, carpet 
cleaner, or similar products, turn heater off. 
If heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture.
9.  This fireplace needs fresh air ventilation to run 
properly. This fireplace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS shuts down the fireplace if enough fresh 
air is not available. See Air for Combustion and 
Ventilation, page 5. If fireplace keeps shutting 
off, see Troubleshooting, page 23.
10.  Do not run fireplace
• where flammable liquids or vapors are used 
or stored
• under dusty conditions
11.  Do not use this fireplace to cook food or burn 
paper or other objects.
12.  Do not use fireplace if any part has been exposed 
to or under water. Immediately call a qualified 
service technician to inspect the fireplace and to 
replace any part of the control system and any 
gas control which has been under water. 
13.  Do not operate fireplace if any log is broken. 
Do not operate fireplace if a log is chipped 
(dime-sized or larger). 
14.  Turn fireplace off and let cool before servicing. 
Only a qualified service person should service 
and repair fireplace.
15.  Operating fireplace above elevations of 4,500 
feet could cause pilot outage. 
16.  To  prevent  performance  problems  in 
propane/LP units, do not use propane/LP 
fuel  tanks  of  less  than  100  lbs.  capacity 
(propane/LP units only).
17.  Provide  adequate  clearances  around  air 
openings.
PRODUCT 
IDENTIFICATION
Figure 1 - Log Base Assembly
Optional 
Blower 
Assembly
(Not 
Included)
Top Louver 
Assembly 
Fireplace 
Hood 
Bottom 
Louver 
Assembly 
Screen 
Assembly 
Top Outer Casing 
Firebox 
Support 
Figure 2 - Fireplace
LOCAL CODES
Install and use fireplace with care. Follow all local 
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI 
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269
Note:
 Where listed vented decorative logs are 
required, thermostat operation is not permitted.
Optional 
Remote 
Control
Log Set
Base 
Assembly
Front 
Burner
Rear 
Burner