Cal Flame LTR20091006 ユーザーズマニュアル

ページ / 32
18
Installation / 
Assemb
ly
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
low a controlled amount of air flow through the screen and into the 
fuel supply tube. Flame should have good retention. For a proper 
burn and as a general rule, the air shutter for propane installation 
should be completely open, and the air shutter for NG installation 
should  be  mostly  closed.  This  can  be  adjusted  later  to  create  a 
clean and desired flame.  
Refer to photo below for proper placement of parts. The washer 
5. 
should insert next to the protective screen cover, then the spring is 
to be aligned with the hole and finally the natural gas orifice is to 
be threaded into the end of the fuel inlet leading into the burner. 
Once tight the other brass fitting connection can be made from the 
fuel line fitted between the valve and the orifice.
Connect natural gas supply hose (not included with kit) from sup-
6. 
ply source. Test for leaks. 
Once the conversion is completed and leak tested, reload the fire-
7. 
place or firepit with the lava rocks and fire logs. Test the unit while 
in place and verify it works properly. If flame from burner is not 
properly adjusted you can adjust air intake by turning the protec-
tive screen cover and air intake sleeve on the fuel supply tube.
Orifice 
assembly 
for fire pit 
burners
Orifice 
assembly 
for fireplace 
burners