Corner Tabs
Self locking tab
Tab cut-out
Fig. 1
Fig. 2
JUN07.0201
The following instructions apply to recirculating kit part numbers ZRC-0000, ZRC-0001, ZRC-0002, ZRC-0003, 
ZRC-0010, ZRC-0070 and ZRC-0080.
Charcoal filters are not meant to be cleaned.  Do not place charcoal filters in the dishwasher or soak them in soapy 
water.  Under normal usage (1 hour per day) filters should be replaced every 3 - 4 months.   Charcoal filters may need 
to be replaced more frequently depending on cooking style.
Charcoal Filter Bracket Instructions
Corner lip
of bracket
*note:  Filter bracket appearance may be slightly different from the bracket pictured.
1. Install metal bracket* onto metal filter from 
hood by sliding one end of the metal bracket 
underneath the backside of the gray handle 
as shown.
2. Push two corner tabs into metal filter frame 
to lock them in.  If pushing tabs is difficult, 
gently lift up on the corner lip of the bracket 
near the gray handle and push down on the 
corner tab. (Fig.1)
3. Install charcoal filter onto metal bracket 
with platic side up.  Insert bottom side of 
carbon filter where the tab cut-outs are first.  
(Fig.2)
4. Push charcoal filter down until it clicks, 
locking tabs in place.
5. Installation complete.  Install metal filter 
into range hood.