Lennox Hearth E260 ユーザーズマニュアル

ページ / 18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Model
F (1)
G
H
J
M
C260  
22”
559mm
14”
356mm
22-1/2”
572mm
5-1/4”
133mm
50-1/2” 
1283mm
E260  
22”
559mm
14”
356mm
22-1/2”
572mm
5-3/4”
133mm
45”
1143mm
C260 with mantel 
and/or side 
shields 
u
22”
559mm
14”
356mm
22-1/2”
572mm
5-1/4”
133mm
38”
965mm
*  Reduced  clearances  may  be  available  for  A,  B,  C  and  D 
dimensions  per  NFPA  211  -  latest  edition,  Standard  for 
Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appli-
ances (in Canada CSA B365 - latest edition). See section on 
“Reduction of Appliance Clearance with Specified Forms of 
Protection.” 
** Side view of optional mantel deflector shown.
u
Elite™ E260 - Not tested for reduction of clearances
(1)Hearth extension reductions: 2” (51mm) reduction for 2” 
(51mm) raised hearth.  (USA) 16” minimum hearth exten-
sion on all stoves as measured from the door opening of the 
unit. (Canada) 18”(450mm) minimum hearth extension on 
all stoves as measured from the door opening of the unit. 
Minimum distance of floor protection to the side = 8” (200mm). 
This is measured from the sides of the door opening in the 
USA and from the sides of the insert in Canada.
H
eartH
 P
rotection
The hearth and/or floor protection must be a thermally rated 
non-combustible hearth/floor protector meeting or exceeding 
a thermal rating of k=.84 or equivalent with a listed thickness 
of listed thickness of 3/4" (19mm) minimum in the USA and 
Canada.  The  covering  must  extend  USA-16”/Canada-18”  
(C260) and 22” (E260) in front of the heater and 8” to the 
side (measured from door opening in the USA and measured 
from the side of the unit in Canada).
Top Facing / Trim
Side Facing Materia
l
SIDE WALL
C
E (USA)
D
B
A
COMBUSTIBLE MANTEL
Insert
Maximum Mantel Depth = 9” (229 mm)
Hearth Protection
(Canada)
M
6-1/2”
165mm
F
**
J
G
H
Mantel
Hearth Protection
Trim
Model
*A
*B
*C 
*D
E(1)
C260  
30”
762mm
20”
508mm
20”
508mm
15”
381mm
8”
200mm
E260  
23”
584mm
1”
432mm
20”
508mm
15”
381mm
8”
200mm
C260 with mantel 
and/or side 
shields 
u
30”
762mm
20”
508mm
20”
508mm
15”
381mm
8”
200mm
Notes
•  Facing material that projects more than 3/4” (19mm) from 
the wall is considered a mantel or side wall.
•  MINIMUM  FIREPLACE  OPENING  22-1/2”  (52mm)  High  x 
28-1/2” (24mm)
r
equired
 c
learances
WARNING:    BE  ABSOLUTELY  SURE  THE  DISTANCE  BE-
TWEEN THE HEATER AND THE SURFACE OF ANY COM-
BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN 
ON THIS PAGE.
Figure 4
Figure 5