LP Hose and Regulator
To reduce the risk of serious bodily injury or death 
from fire or explosion:
• Clean and inspect the gas hose/regulator before 
each use of the outdoor cooking gas appliance. 
The gas hose/regulator must be replaced prior to 
being used, if there is evidence of excessive abra-
sion or wear, or if the hose is cut or leaks. 
• Use only the gas hose/regulator assembly that 
has been supplied with this gas grill. Do not 
use hose/regulator from another manufacturer. 
Replacement gas hose/regulator assembly must be 
specified by this grill’s manufactuer before using.
• Always check for gas leaks when you connect 
and disconnect the hose/regulator to the LP Gas 
Cylinder, especially after a period of storage (for 
example, over winter).
• Make sure there are no sharp bends in the hose.
• Make sure the hose/regulator does not contact any 
heated surfaces.
WARNING
!
NOTE: 
If the hose/regulator assembly is not working properly 
and you need a replacement, contact Customer Service 
at 1-800-251-7558
 or go to www.aussiegrills.com.
Be sure to have the grill model number and serial 
number
 printed on the black label, located inside the 
left door of the cabinet. If you need a replacement 
part under warranty, a proof of purchase will be 
necessary. You will be asked to forward your proof of 
purchase via e-mail or to fax your proof of purchase 
to 423-639-1055 and reference your model and serial 
number. It is important to register your grill and 
retain your receipt.
Connecting LP Gas Cylinder
1. Fill empty OPD LP Gas Cylinder at your local gas supplier. 
2. Place the LP Gas Cylinder in the large hole in the Bottom Panel inside the cabinet. Rotate the LP Gas Cylinder so the 
Cylinder nozzle is toward the door opening for proper vapor withdrawal. Lock the LP Cylinder in place by tightening 
wing bolt on the outside rear of the cabinet base so that it seats against the ring base of the LP Cylinder.
3. Remove the protective cap from the LP Gas Cylinder valve. (Save cap for re-capping.) Hold Regulator in a straight 
line with LP Gas Cylinder valve so the connection does not cross thread. Insert Regulator Nipple into the LP Gas 
Cylinder valve. Hand tighten coupling nut in clockwise direction. DO NOT USE TOOLS.
Disconnecting LP Gas Cylinder
1. Turn all Control Knobs to the “Off” position and turn the handle on the LP Gas Cylinder clockwise until it stops.
2. Turn coupling nut on regulator counterclockwise until regulator is released from the threaded LP Gas Cylinder 
nozzle.
3. Place the protective cap over LP Gas Cylinder nozzle.
Hand-tighten coupling nut 
in clockwise direction
Cylinder nozzle 
faces out 
toward door
Wing Bolt on outside 
rear of cabinet base