Planning the Installation
Location Planning - General
Gas and Electric Power Requirements
Prior to installation, the gas supply for natural gas or 
whole house LP installations must meet the specifica-
tions below.
For natural gas or whole house LP installations, have a 
qualified plumber or gas fitter install a 3/4 inch (19mm) 
or 1/2 inch (13mm) gas supply line with a shut-off valve 
(not included). Have it installed in an accessible loca-
tion that allows it to be shut off when the appliance is 
installed.
gas supply requirements
Model Type
Manifold pressure
Minimum gas 
supply pressure
Natural Gas
4” Water Column
5” Water Column
LP Gas
11” Water Column
12” Water Column
Correct voltage, frequency and amperage must be sup-
plied to the appliance from an isolated, grounded circuit 
which is protected by a properly sized circuit breaker or 
time-delay fuse. The required voltage, frequency, and 
amperage ratings are listed on the product data plate 
and are also below.
electrical requirements
Circuit Requirement
120 Vac, 15 Amp.
Total Connected Load
2.9 Amps, (0.35 kW)
It is the owner’s responsibility to ensure that the elec-
trical connection to this appliance is installed by a 
qualified electrician. The electrical installation, includ-
ing minimum supply wire size and grounding, must be 
done in accordance with National Electric Code ANSI/
NPFA 70, (or the latest revision) or Canadian Electrical 
Code CSA C22.1, and local codes and ordinances for 
connection of an outdoor appliance.
Locate the electrical outlet within reach of the 48 Inch 
(1219mm) long power cord so that it will reach when 
the grill is completely installed in the enclosure.
Total connected loads shown include the ignition sys-
tem, interior lights and rotisserie motor.
The rotisserie motor should be plugged into the same 
grounded outlet power source or an alternate 120 Vac 
duplex outlet located on the same circuit as the grill.
 warning
This installation must conform to local codes or, in the 
absence of local codes, with either the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and 
Propane Installation Code, CSA B149.1, or Propane 
Storage and Handling Code, B149.2.
Prevent grill combustion products from being drawn 
into a building through fresh air inlets: The venting 
system of other than a direct-vent appliance must 
terminate at least 4 feet (1.2m) below, 4 feet (1.2m) 
horizontally from, or 1 foot (305mm) above any door, 
window or gravity air inlet into any building. The bot-
tom of the vent terminal must be located at least 12 
inches (305mm) above grade.
A MINIMUM clearance of 10 inches (254mm) must be 
maintained, above the countertop material, from all 
combustible vertical materials on the sides and behind 
the outdoor grill chassis and canopy.
On all models except OBSB162, a MINIMUM clear-
ance of 1 1/4 inches (32mm) must be maintained, 
above the countertop material, from all non-combus-
tible vertical materials on the sides and behind the 
outdoor grill chassis and canopy.
On model OBSB162, a MINIMUM clearance of 2 inch-
es (51mm) must be maintained, above the countertop 
material, from all non-combustible vertical materials 
on the sides and behind the chassis.
A MINIMUM clearance of 1/4 inch (6mm) must be 
maintained, inside the base enclosure below the 
countertop material, from all vertical surfaces on the 
sides of the appliance, except on model OBSB162. 
On model OBSB162 a minimum clearance of 1/4 inch 
(6mm) must be maintained in back and 1/16 inch on 
the sides.
A MINIMUM clearance of 3/4 inch (19mm) must be 
maintained, from the bottom of the control panel to 
any material for ventilation purposes. Failure to do so 
will block air flow through the outdoor grill and may 
cause carbon monoxide poisoning or improper opera-
tion.
The back edge of the grill must maintain a minimum 
clearance (10 inches/254mm) from combustible back 
splash materials. Special cabinet and countertop 
dimensions are required.
The electrical outlet and gas service must be installed 
only by a qualified, licensed professionals.
The maximum gas supply pressure to the regulator 
must not exceed 1/2 pound per square inch.
Use only the factory supplied gas regulator or a Dacor 
approved replacement.