Aussie 6804T80SS1 ユーザーズマニュアル

ページ / 38
33
Emergencies
Problem
Gas leaking from 
cracked/cut/burned hose
Gas leaking from 
LP Gas Cylinder
Gas leaking from LP Gas 
Cylinder valve
Gas leaking between 
LP Gas Cylinder and regula-
tor connection
Fire coming through Control 
Panel
Grease fire or excessive 
flames above cooking surface
Flashback (Fire in or around 
Venturi tubes)
Possible Cause
Damaged hose
Mechanical failure due to rust 
or mishandling
Failure of valve from mishan-
dling or mechanical malfunc-
tion
Improper installation, con-
nection not tight, failure of 
seal on LP Gas Cylinder valve
Fire in or around Venturi tube 
section of Burner
Too much grease build-up in 
Burner section
Clogged or blocked Venturi 
tube
Solution
Turn off gas at the LP Gas Cylinder. Replace valve/hose 
regulator before continuing use.
Replace LP Gas Cylinder.
Turn off LP Gas Cylinder valve. Return Cylinder to 
gas supplier.
Turn off LP Gas Cylinder valve. Re-install correctly or 
tighten coupling nut. Replace Cylinder if seal is dam-
aged. See “Leak Test” and “Connecting Regulator 
to LP Gas Cylinder”
 sections.
If you can safely reach the Control Panel, turn off Control 
Knobs, then close the LP Gas Cylinder valve. Once fire 
is out and grill has cooled off, remove Burner(s) and 
inspect for blockage from spider webs/insect nests or 
rust. See “How to Clean Burners” section. Replace 
any damaged parts.
Turn off Control Knobs and LP Gas Cylinder valve. 
Once fire is out and grill has cooled off. Clean residual 
food particles and excess grease from inside firebox 
area, grease cup, and other surfaces.
If you can safely reach the Control Panel, turn Control 
Knobs to “Off,” then close the LP Gas Cylinder valve. 
Clean Burner and Venturi tubes. See “How to Clean 
Burners” section.
Troubleshooting
Problem
Burners will not light using 
the ignitor
Possible Cause
Burners not assembled correctly
Not holding ignitor switch long 
enough for pulse spark
No spark, electrode cracked, 
broken or loose.
LP gas cylinder is empty
Solution
See re-assembly after cleaning in 
“Care and Maintenance.”
When lighting the first (LEFT MOST) Burner, push Control 
Knob in and turn counterclockwise to the “High” position. 
Depress the Igniter Button until the Burner lights.
1.   Make sure all the wires are connected and to the right  
 terminals.
2.   If Electronic, check the battery. Make sure it is pushed in  
 the holder.
3.  Gas collector tab is bent (making too large or small of  
  a gap between the Electrode and tab). By hand, bend  
  gas collector tab back within a maximum of 3/16” gap  
  to Electrode. (Page 20)
4.  Tighten Electrode mounting screws.
5.  Replace damaged Electrodes.
Take LP Gas Cylinder to licensed LP gas supplier to be refilled.