NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
 Input (BTU/HR) Manually-Modulated Gas 
Valves (millivolt models)
Model
NATURAL GAS
(BTU / HR)
PROPANE GAS 
(BTU / HR)
ADAGIO-MN
1,000 high
10,000 low
-------------
ADAGIO-MP
-------------
1,000 high
10,000 low
Table 1
 Input (BTU/HR) Electronic Models 
Model
NATURAL GAS
(BTU / HR)
PROPANE GAS 
(BTU / HR)
ADAGIO-EN
1,000 high
10,000 low
-------------
ADAGIO-EP
if field converted
-------------
1,000 high
10,000 low
Table 2
Burner Orifice Sizes 
Elevation 0-4500 feet ( 0-172 meters)
Model
Series
Nat.Gas
drill size (inches)
Propane
drill size (inches)
ADAGIO-MN
#51
-------------
ADAGIO-MP
-------------
#58
ADAGIO-EN
#51
-------------
ADAGIO-EP
if field converted
-------------
#58
Table 5
Electronic Models - 
Electronic models have a manually modulated
gas valve. Input of electronic models is shown
in the following table:
These appliances are designed to operate on 
natural or propane gas only. The use of other 
fuels  or  combination  of  fuels  will  degrade 
the performance of this system and may be 
dangerous.
Millivolt Models - 
Millivolt models come standard with the manu-
ally-modulated gas valve; flame appearance and
heat output can be controlled at the gas valve.
Input of millivolt models is shown in the fol-
lowing table:
Gas Pressure - All Models 
Tables 3 and 4 show the appliances' inlet and 
manifold gas pressure.
Inlet Gas Supply Pressure 
(all models)
Fuel #
Minimum
Maximum
Natural Gas
5.0" WC
(1.24 kPa)
10.5" WC
(2.61 kPa)
Propane
11.0" WC
(2.74 kPa)
1.0" WC
(.2 kPa)
Table  3
Manifold Gas Supply Pressure
(all models)
Fuel #
Low
High
Natural 
Gas
(Lo) 2.2" WC
(.55 kPa)
(Hi) .5" WC
(.87 kPa)
Propane (Lo) 6." WC
(1.57 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table  4
Test gauge  connections  are  provided  on  the
front of the millivolt and electronic gas control
valve (identified IN for the inlet and OUT for
the manifold side). The control valves have a
3/8" (10 mm) NPT thread inlet and outlet side
of the valve.
These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve) during any
pressure  testing  of  the  gas  supply  piping
system  at  test  pressures  equal  to  or
less 
than 1/2 psig (3.5 kPa).
These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures
greater 
than 1/2 psig (3.5 kPa).
Orifice Sizes - Sea Level To High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters)  above  sea  level,  using  the  standard
burner orifice (See
Table 5). For elevations
above  4500  feet,  contact  your  gas  supplier
or  qualified  service  technician.    Install  the
appliance according to the regulations of the
local authorities having jurisdiction and, in the
USA,  the  National  Fuel  Gas  Code  NFPA  54  /
ANSI Z223.1 - latest edition or , in Canada, the
CAN1-B149.1 and .2 codes - latest edition.
Table  5  shows the gas orifice size required 
for the elevations indicated.
       WARNING 
Propane  tanks  are  at  pressures 
that will cause damage to valve 
components.  Verify  that  the 
tanks have step down regulators 
to  reduce  the  pressure  to  safe  
levels.
The millivolt appliances are manually controlled
and feature a spark igniter (piezo) that allows the
appliance's pilot gas to be lit without the use of
matches or batteries. This system provides con-
tinued service in the event of a power outage.
Do  not  use  these  appliances  if  any  part  has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the control
system and any gas control which have been
under water.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifié pour inspecter l'appareil et
remplacer toute partie du système de contrôle
et toute commande qui ont été plongés dans
l'eau.
This appliance is only for use with the type 
of  gas  indicated  on  the  rating  plate.  This 
appliance  is  not  convertible  for  use  with 
other  gases,  unless  a  certified  kit  is  used.
Cet  appareil  doit  être  utilisé  uniquement 
avec les types de gaz indiqués sur la plaque 
signalétique.  Ne pas l'utiliser avec d'autres 
gaz sauf si un kit de conversion certifié est 
installé.
These appliances must not be connected to a 
chimney or flue serving a separate solid fuel 
burning appliance.
Carbon Monoxide Poisoning: Early signs of 
carbon monoxide poisoning are similar to the 
flu with headaches, dizziness and/or nausea. 
If you have these signs, obtain fresh air im-
mediately. Have the appliance serviced by a 
qualified technician as it may not be operating 
correctly.  Some people are more affected by 
carbon monoxide than others.  These include 
pregnant women, people with heart or lung 
disease or anemia, those under the influence 
of alcohol, and those at high altitudes.