CLEANING AND MAINTENANCE
Continued
INSPECTING BURNERS
Continued
Figure 30 - Incorrect Burner Flame Pattern
Dark Orange 
Flames
CLEANING AND MAINTENANCE
 
WARNING: Turn off appliance and let cool 
before cleaning.
  CAUTION:  You  must  keep  control  areas, 
burners and circulating air passageways of ap-
pliance clean. Inspect these areas of appliance 
before  each  use.  Have  appliance  inspected 
yearly by a qualified service person. 
 WARNING: Failure to keep the primary air 
opening(s) of the burner(s) clean may result 
in sooting and property damage.
BURNER INjECTOR HOLDER AIR INLET HOLE
The primary air inlet holes allow the proper amount of air to 
mix with the gas. This provides a clean burning flame. Keep 
these holes clear of dust, dirt, lint and pet hair. Clean these air 
inlet holes prior to each heating season. Blocked air holes will 
create soot. We recommend that you clean the unit every three 
months during operation and have appliance inspected yearly 
by a qualified service person. 
We also recommend that you keep the burner tube clean and 
free of dust and dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI. Your local computer 
store, hardware store or home center may carry compressed 
air in a can. If using compressed air in a can, please follow 
the directions on the can. If you don’t follow directions on the 
can, you could damage the pilot assembly.
1.  Shut off unit. Allow unit to cool for at least thirty minutes.
2.  Inspect burner, and primary air inlet holes on injector holder 
for dust and dirt (see Figure 31).
3.  Blow air through the ports/slots and holes in the burner.
4.  Check injector holder located at end of burner tube again. 
Remove any large particles of dust, dirt, lint or pet hair with 
a soft cloth or vacuum cleaner nozzle.
5.  Blow air into the primary air holes on the injector holder.
6.  In case any large clumps of dust have now been pushed 
into the burner repeat steps 3 and 4. Additional cleaning 
may be needed for proper operation based on use/lack of 
use.
Figure 31 - Injector Holder On Outlet Burner Tube
Burner Tube
Injector 
Holder
Primary Air 
Inlet Holes
LOGS
•  If you remove logs for cleaning, refer to Installing Logs and 
Lava Rock, page 10, to properly replace logs.
•  Replace log(s) if broken or chipped (dime-sized or larger).
MAIN BURNER
Periodically inspect all burner flame holes with appliance running. 
All slotted burner flame holes should be open with flame present. 
All round burner flame holes should be open with a small blue 
flame present. Some burner flame holes may become blocked 
by debris or rust, with no flame present. If so, turn off appliance 
and let cool. Remove blockage, blocked burner flame holes will 
create soot.
 
WARNING: The injector holders (air shut-
ters) are not adjustable. Do not move injector 
holders from their original positions.
SPECIFICATIONS
MF42ONE AND MF48ONE 
•  Rating (Variable): 29,000/40,000 Btu/Hr
•  Type Gas: Natural
•  Ignition: Electronic
•  Manifold Pressure: 3.4" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
MF42OPE AND MF48OPE
•  Rating (Variable): 29,000/40,000 Btu/Hr
•  Type Gas: Propane/LP
•  Ignition: Electronic
•  Manifold Pressure: 10.0" W.C.
•  Inlet Gas Pressure (in. of water):
  Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment