TROUBLESHOOTING
 
WARNING: Turn off appliance and let cool before servicing. Only a qualified service person 
should service and repair appliance.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor electrode not connected to 
ignitor cable
2. Ignitor cable pinched or wet
3. Broken ignitor cable
4. Bad ignitor
5. Ignitor  electrode  positioned 
wrong
6. Ignitor electrode broken
7. Battery  not  installed,  battery 
power low or battery not installed 
correctly (electronic ignition mod-
els only)
1. Gas  supply  turned  off  or  equip-
ment shutoff valve closed
2. Air in gas lines when installed
3. Depleted  gas  supply  (propane/
LP only)
4. Control module not in REMOTE 
position
5. Gas control valve pressure setting 
is not correct
6. Inlet gas pressure is too low
7. Burner orifice(s) clogged
8. Wire disconnected from gas con-
trol
REMEDY
 
1. Reconnect ignitor cable
2. Free  ignitor  cable  if  pinched  by 
any metal or tubing. Keep ignitor 
cable dry
3. Replace ignitor
4. Replace ignitor 
5. Adjust ignitor wires as shown in 
Figure  28  on  page  15.  Replace 
ignitor  assembly  if  repositioning 
does not correct the problem
6. Replace ignitor
7. Install  new  alkaline  battery  in 
remote control and battery pack. 
Verify batteries are installed cor-
rectly
1. Turn on gas supply or open equip-
ment shutoff valve
2.  Repeat igniting operation until air 
is removed
3. Contact  local  propane/LP  gas 
company
4. Set control module to REMOTE 
position
5. Contact qualified service person 
to check pressure
6. Contact local natural or propane/
LP gas company
7. Clean burner (see Cleaning and 
Maintenance, page 16) or replace 
burner orifice(s)
8. See Wiring Diagram, page 17
OBSERVED PROBLEM
When ''ON'' button on remote control 
is pressed, there is no park at ignitor 
assembly
When ''ON'' button on remote control 
is pressed, there is spark at ignitor. 
but no ignition