Masterbuilt 20051011 ユーザーズマニュアル

ページ / 11
3
SOAPY WATER TEST WARNINGS & PROCEDURES
REGULATOR, BURNER AND GAS VALVE CONNECTION & OPERATION
MATCH LIGHT INSTRUCTIONS
WARNINGS
 •  Soapy Water Test MUST be performed each time gas cylinder is connected to burner/hose or each time it 
    is used.
 •  Soapy Water Test MUST be performed outdoors in well ventilated area.
 •  When performing Soapy Water Test keep smoker away from open fl ames, sparks or lit cigarettes.
 •  Smoker is designed to work with propane gas only. Only use gas cylinders marked propane with this unit.  
   This product will NOT operate with natural gas.
 •   Never use an open fl ame to test for gas leaks.
PREPARATION:
 •  Remove any cookware from smoker.
 •  Make sure regulator and gas cylinder valve to OFF position.
 •  Prepare soapy water solution: (1) part dish washing liquid (or more if desired), (3) parts water.
 •  Apply soapy water solution to gas cylinder valve, regulator and hose length up to burner.
TESTING GAS VALVE:
 •  Turn gas cylinder valve ON and watch for bubbles.  DO NOT LEAVE GAS ON MORE THAN 
    12 SECONDS.  If bubbles appear, stop, turn gas cylinder OFF and retighten fi tting. Repeat test.
TESTING REGULATOR AND HOSE:
 •  AFTER gas cylinder valve has passed Soapy Water Test, turn gas cylinder valve ON, open regulator 
    control valve one full turn and check for bubbles at valve location, along full length of hose and at burner 
    connection.  DO NOT LEAVE GAS ON MORE THAN 12 SECONDS.  If bubbles appear, stop, turn 
    regulator valve OFF, turn gas cylinder OFF and retighten the connection that is leaking gas.  If hose is 
    source of leak, STOP, do not use unit.  Hose must be replaced.
 •  When test is complete, and there are no leaks, wait minimum of 5 minutes for gas fumes to diminish 
    before lighting cooker.
DURING ANY PORTION OF SOAPY WATER TEST IF BUBBLES CONTINUE TO
APPEAR, STOP, DO NOT USE UNIT.  CONTACT LOCAL PROPANE DEALER OR
MASTERBUILT CUSTOMER SERVICE @ 1-800-489-1581.
Note: Use 20LB (9kgs) gas cylinder that has a protective collar with this unit. 
Cylinder NOT included with this unit.
Apply solution to 
gas cylinder valve
Apply solution to hose regulator 
and the full length of the hose
Apply solution underneath control 
panel where burner and hose are 
connected
Failed test will present bubbles as 
shown below.
(Smoker shown on back for clarity only)
WARNING
PERFORM “SOAPY WATER TEST” BEFORE EACH USE. SEE “SOAPY WATER TEST” SECTION IN 
MANUAL. EXTINGUISH ALL OPEN FLAMES BEFORE CONNECTING REGULATOR TO GAS 
CYLINDER. TURN GAS OFF AFTER EACH USE.
• Inspect hose before each use.  If there are signs of wear, cuts, or leaks, replace
  unit.  DO NOT USE.
• Inspect burner before each use.  Check burner and burner ventura tube for
  insects and insect nests.  A clogged tube can lead to a fi re beneath appliance.
• Connect hose regulator to LP Gas Cylinder
 
1. Make sure gas cylinder valve is closed.  Turn knob clockwise until it stops.
 
2. Make sure control knob on smoker is in the “OFF” position.
 
3. Remove protective cap from gas cylinder and coupling nut if applicable.
 
4. Center and insert regulator nipple into valve outlet on gas cylinder as
 
    shown in fi gure on the left.  Turn regulator coupling nut clockwise until it
 
    stops.  DO NOT OVER TIGHTEN.  
• Perform Soapy Water Test.
• To use turn gas cylinder ON, turn regulator control valve ON, push burner control
  knob in and turn counter-clockwise ¼ turn. Push ignitor button to light. 
• If ignition does not take place within fi ve seconds, turn gas control valve to off
  position and wait fi ve minutes and repeat lighting procedures. If ignition still does 
  not occur, see match light directions below.
• After use turn burner control knob OFF, turn regulator control valve OFF, then turn 
gas cylinder OFF.
• Burner control knob adjusts burner fl ame. Turn knob counter-clockwise to decrease 
  fl ame. Turn knob clockwise SLOWLY to increase fl ame.  Push burner control knob 
  in and turn clockwise to shut fl ame off.
• Visually check burner fl ame.  A CORRECT FLAME should be blue with a small
  amount of yellow at the tip.  An INCORRECT FLAME is excessively yellow and
  irregular.  If an incorrect fl ame occurs, turn burner control knob to “OFF position,
  turn off regulator and propane tank.  Allow unit to cool and then clean burner.  
  Let burner completely dry before re-lighting.
CLOCKWISE
COUNTER 
CLOCKWISE
17.75”
(45cm)
APPROX.
12.25” (45cm)
APPROX.
YELLOW
BLUE
1. Read all instructions and warnings before lighting.
2. Check gas control valve and gas cylinder valve to be certain it is in 
    OFF position before connecting to gas cylinder. Perform soapy 
    water test before each use.
3. Open door during lighting.
4. Turn gas control valve on, turn gas cylinder valve on.
5. Place a long, lit fi replace match stick close enough to burner to 
    ignite.
6. After each use, fi rst turn gas control valve off, then gas cylinder 
    valve off.  Always allow unit to cool completely before touching, 
    moving or storing.
4