Liebherr 7085638-01 ユーザーズマニュアル

ページ / 12
Fig. 7 
u
Lift the stopper
 Fig. 7 (33)
 out of the door bearing bush and
transfer it.
u
Dismantle the door handle
 Fig. 7 (32)
, stoppers
 Fig. 7 (33)
and pressure plates*
 Fig. 7 (34)
 and transfer to the opposite
side.
u
When fitting the pressure plates on the opposite side, make
sure they snap properly into place.*
4.3.4 Fitting the door
u
Place  the  door  from  above  onto  the  lower  bearing  pin
Fig. 5 (22)
.
u
Close the door.
u
Insert the upper turn hinge
 Fig. 4 (12)
 in the door on the new
hinge side.
u
Screw the upper turn hinge
 Fig. 4 (12)
firmly into place (with
4 Nm)(2x Torx® 25)
 Fig. 4 (13)
. Possibly make preliminary
holes with a bradawl or use a cordless screwdriver.
u
Snap the cover
 Fig. 4 (10)
 and cover
 Fig. 4 (11)
 into place at
the opposite side.
4.3.5 Aligning the door
u
Align  the  door  to  the  appliance  housing  by  way  of  the  two
oblong holes in the bottom turn hinge
 Fig. 5 (25)
. To do so,
unscrew the middle screw.
WARNING
Risk of injury due to the door dropping out!
If the bearing parts are not screwed into place firmly enough,
the door may drop out. This may lead to severe injuries. What
is  more,  the  door  may  not  close  and  therefore  the  appliance
may fail to cool properly.
u
Screw the turn hinges firmly into place with 4 Nm.
u
Check all of the screws and retighten if necessary.
4.4 Insertion into a row of kitchen units
Fig. 8 
(1) Stack cabinet
(3) Kitchen cabinet
(2) Appliance
(4) Wall
x
 For appliances supplied with wall spacers, the measurement
increases by 35 mm (see 4.2) .
The appliance can be inserted into a row of kitchen units. To
match the appliance
 Fig. 8 (2)
 to the height of the row of units,
a suitable stack cabinet
 Fig. 8 (1)
 can be fitted above the appli-
ance.
When  installing  with  kitchen  units  (max.  depth  580  mm),  the
appliance can be positioned directly next to the kitchen cabinet
Fig. 8 (3)
. The appliance will project by 34 mm
at the sides and
50 mm
in the centre of the appliance in relation to the kitchen
cabinet front.
Ventilation requirements:
-
At the back of the stack cabinet there has to be a ventilation
duct  of  at  least  50  mm  depth  throughout  the  width  of  the
stack cabinet.
-
The  ventilation  space  under  the  ceiling  has  to  be  at  least
300 cm
2
.*
-
the larger the ventilation space, the more energy-saving the
appliance is in operation.
If  the  appliance  is  installed  with  the  hinges  next  to  a  wall
Fig. 8 (4)
, the distance between appliance and wall has to be at
least 40 mm. This corresponds to the projection of the handle
when the door is open.
4.5 Disposing of packaging
WARNING
Danger of suffocation due to packing material and plastic film!
u
Do not allow children to play with packing material.
Putting into operation
* Depending on model and options
7