Mitsubishi Electronics QD75P4 ユーザーズマニュアル

ページ / 860
 
 
 
1 - 13 
MELSEC-Q
1   PRODUCT OUTLINE 
 
 QD75   CPU module 
The QD75 and CPU module communicate the following data via the base unit. 
 
Direction 
Communication 
QD75 
  CPU module 
CPU module 
 QD75 
Control signal   
Signal indicating QD75 state, such as 
QD75 READY signal, BUSY signal. 
Signal related to commands such as PLC 
READY signal, various start signals, stop 
signals 
Data (read/write) 
• Parameter 
• Positioning data 
• Block start data 
• Control data 
• Monitor data 
• Parameter 
• Positioning data 
• Block start data 
• Control data 
 
  Refer to Section 3.3 "Specifications of input/output signals with CPU module " for details. 
 
 QD75   Peripheral device 
The QD75 and peripheral device communicate the following data via the CPU 
module: 
 
Direction 
Communication 
QD75 
  Peripheral device 
Peripheral device 
 QD75 
Data (read/write) 
• Parameter 
• Positioning data 
• Block start data 
• Parameter 
• Positioning data 
• Block start data 
Test operation 
– 
• OPR control start command 
• Positioning control start command 
• JOG/Inching operation start command 
• Teaching start command 
• Manual pulse generator operation   
  enable/disable command 
Operation monitor 
• Monitor data 
– 
 
 QD75   Drive unit 
The QD75 and drive unit communicate the following data via the external device 
connection connector. 
 
Direction 
Communication 
QD75 
  Drive unit 
Drive unit 
 QD75 
Control signal 
Signals related to commands such as 
deviation counter clear signal 
Signals indicating drive unit state such as 
drive unit READY signal 
Pulse train 
• Pulse train output 
– 
 
 QD75    Manual pulse generator 
The QD75 and manual pulse generator communicate the following data via the 
external device connection connector. 
(The manual pulse generator should be connected to an external device connection 
connector for axis 1 or for axes 1 and 2.) 
 
Direction 
Communication 
QD75 
  Manual pulse generator 
Manual pulse generator 
 QD75 
Pulse signal 
– 
Manual pulse generator A-phase, manual 
pulse generator B-phase