Mitsubishi Electronics QD75D2N ユーザーズマニュアル
13 - 8
MELSEC-Q
13 COMMON FUNCTIONS
13.5 External I/O signal monitor function
The "external I/O signal monitor function" monitors the module's information and
external I/O signal monitor information in the module's detailed information which
can be displayed on the system monitor of GX Developer 1.
external I/O signal monitor information in the module's detailed information which
can be displayed on the system monitor of GX Developer 1.
The information that can be monitored are the module's information (same as the
QD75 front "RUN", "ERR" LED indicators) and the following external I/O signals.
(Set the logic of the external I/O signals in " Pr.22 Input signal logic selection"
and " Pr.23 Output signal logic selection".)
QD75 front "RUN", "ERR" LED indicators) and the following external I/O signals.
(Set the logic of the external I/O signals in " Pr.22 Input signal logic selection"
and " Pr.23 Output signal logic selection".)
Indicates that Drive unit ready of axis 1 is ON.
0:OFF, 1:ON
Axis-by-axis external I/O
signals and module RUN,
ERR LEDs
signals and module RUN,
ERR LEDs
1: For the QD75P /QD75D , this function is available in GX Developer
(SW6D5C-GPPW-E or later). For details, refer to GX Developer Operating
Manual.
For the QD75P N/QD75D N, external I/O signals cannot be monitored on
GX Developer. Use the system monitor of GX Works2. For details on the
system monitor of GX Works2, refer to GX Works2 Version 1 Operating
Manual (Common).
Manual.
For the QD75P N/QD75D N, external I/O signals cannot be monitored on
GX Developer. Use the system monitor of GX Works2. For details on the
system monitor of GX Works2, refer to GX Works2 Version 1 Operating
Manual (Common).