3. I/O 
PARAMETERS 
3.2 
I/O Device Parameters 
II - 18 
 
Item 
Contents 
Setup range (unit) 
9113  EIA OUTPUT 
In data output mode, select the ISO or EIA code for 
data output. 
In data input mode, the ISO and EIA codes are 
identified automatically. 
0:  ISO code output 
1:  EIA code output 
9114  FEED CHR. 
Specify the length of the tape feed to be output at 
the start and end of the data during tape output. 
0 to 999 (characters) 
9115  PARITY V 
Specify whether to check the parity of the No. of 
characters in block during data input.  
The No. of characters is factory-set so that the 
check is valid at all times. 
0:  Do not perform 
parity V check 
1:  Perform parity V 
check 
9116  TIME-OUT 
Set the time out time to detect an interruption in 
communication. 
Time out check will not be executed when set to 0 to 
30 seconds. 
0 to 30 (s) 
9117  DR OFF 
Specify whether to check the DR data at the data 
input/output. 
0: DR valid 
1: DR invalid 
9118  DATA ASC II 
0:  Output in ISO/EIA code  (Depends on whether 
#9113, #9213, #9313, #9413, or #9513 EIA 
output parameter is set up) 
1:  Output in ASC II code 
0/1 
9119  INPUT FORM 
Specify the mode for input (collation). 
0:  Standard input (Data from the very first EOB is 
handled as significant information.) 
1:  EOBs following the first EOB of the input data are 
skipped until data other than EOB is input. 
0/1 
9121 
9122 
9123 
9124 
9125 
9126 
9127 
9128 
EIA CODE 
 
 
 
∗ 
 
 
 $ 
 ! 
When output with EIA code‚ data can be output 
using the alternate code in which the special ISO 
code not included in EIA is specified.  
Specify the codes which do not duplicate the 
existing EIA codes by hexadecimal for respective 
special codes. 
0 to FF (hexadecimal)
 
9201 
∼ 
Set the same settings for device 1. 
 
9301 
∼ 
Set the same settings for device 2. 
 
9401 
∼ 
Set the same settings for device 3. 
 
9501 
∼ 
Set the same settings for device 4.