Mitsubishi Electronics E60 ユーザーズマニュアル

ページ / 415
7. SERVO 
PARAMETERS 
7.5 Supplement 
 
II - 213 
 
(c)  Setting the output scale 
When "0" is set, the output will be made with the standard output unit. To change the output unit, set 
a value other than "0". 
The scale is set with a 1/256 unit.  When 256 is set, the unit will be the same as the standard output. 
 
# No. 
Abbrev Parameter 
name 
2263 
SV063
DA1MPY 
D/A output channel 1 
output scale 
2264 
SV064
DA2MPY 
D/A output channel 2 
output scale 
 
(Example 1)  When SV061 = 5, SV063 = 2560 
The V-phase current value will be output with 1 A/V unit to D/A output ch.1. 
 
(Example 2)  When SV063 = 11, SV064 = 128 
The position droop will be output with a 2mm/Vunit to D/A output ch.2. 
 
 
(2)  MDS-C1-Vx, MDS-B-Vx, MDS-B-Vx4 
 
(a)  D/A Output specifications 
 
Item Explanation 
No. of channels 
2ch 
Output cycle 
888µs (min. value) 
Output precision 
8bit 
Output voltage 
0V to 2.5V(zero) to +5V 
Output scale 
setting 
±1/256 to ±128 times 
CN9 connector 
MO1 = pin 9 
MO2 = pin 19 
Output pins 
GND = pin 1,11 
Phase current feed back output function 
L-axis U-phase current FB 
: pin 7 
L-axis V-phase current FB 
: pin 17 
M-axis U-phase current FB 
: pin 6 
Function 
M-axis V-phase current FB 
: pin 16 
Option 
An drive unit with 2 axes also has 2 channels for D/A output.  
Therefore, set the output data of the axis (SV061,62), which 
is not observed, to "-1".