Mitsubishi Electronics E60 ユーザーズマニュアル

ページ / 415
9. 
MACHINE ERROR COMPENSATION 
9.2 
Setting Compensation Data 
II - 292 
 
(3)  Fig. 2. 3 contains a machine position that is placed in the negative direction with respect to the reference 
point. Assume that feed from division point n+1 to n by the division interval is executed. In this case‚ the 
following value is defined as the compensation amount: 
 
(Division interval + Actual movement distance) 
× 2 (Unit of output) 
 
 
n-1 
n+1
n
1
n: Division point compensation number
1: Division interval 
Fig. 2. 2 
Fig. 2. 3 
 
 
Unit 
: Unit of output 
Range  : –128 to 127 
 
(Note) The unit of output is used as the unit of setting. The actual unit of compensation pulses depends on 
the compensation scale factor.