Mitsubishi Electronics E60 ユーザーズマニュアル
13. AUXILIARY AXIS PARAMETER
II - 324
No. Name
Details
Setting
range
Default
value
201
202
202
PSW1dog1
PSW1dog2
PSW1dog2
PSW1 area
setting 1
PSW1 area
setting 2
setting 1
PSW1 area
setting 2
203
204
204
PSW2dog1
PSW2dog2
PSW2dog2
PSW2 area
setting 1
PSW2 area
setting 2
setting 1
PSW2 area
setting 2
205
206
206
PSW3dog1
PSW3dog2
PSW3dog2
PSW3 area
setting 1
PSW3 area
setting 2
setting 1
PSW3 area
setting 2
207
208
208
PSW4dog1
PSW4dog2
PSW4dog2
PSW4 area
setting 1
PSW4 area
setting 2
setting 1
PSW4 area
setting 2
209
210
210
PSW5dog1
PSW5dog2
PSW5dog2
PSW5 area
setting 1
PSW5 area
setting 2
setting 1
PSW5 area
setting 2
211
212
212
PSW6dog1
PSW6dog2
PSW6dog2
PSW6 area
setting 1
PSW6 area
setting 2
setting 1
PSW6 area
setting 2
213
214
214
PSW7dog1
PSW7dog2
PSW7dog2
PSW7 area
setting 1
PSW7 area
setting 2
setting 1
PSW7 area
setting 2
215
216
216
PSW8dog1
PSW8dog2
PSW8dog2
PSW8 area
setting 1
PSW8 area
setting 2
setting 1
PSW8 area
setting 2
When the machine position is in the region
between region settings 1 and 2, the position
switch of each No. will turn ON.
Whether the value of setting 1 is larger than
setting 2 (vice versa) does not affect the
position switch operation.
For rotation axes, the output turns ON at the
region without including 0.000 degree.
between region settings 1 and 2, the position
switch of each No. will turn ON.
Whether the value of setting 1 is larger than
setting 2 (vice versa) does not affect the
position switch operation.
For rotation axes, the output turns ON at the
region without including 0.000 degree.
-99999.999 to
99999.999
(
99999.999
(
° or mm)
0.000
220 push
Stopper
amount
amount
Set the command stroke of the stopper
operation during stopper positioning
operations.
operation during stopper positioning
operations.
0.000 to
359.999
(
359.999
(
° or mm)
0.000
221 pusht1
Stopper
standby time
standby time
Set the standby time from the stopper starting
coordinate positioning to the stopper
operation start during stopper positioning
operations.
coordinate positioning to the stopper
operation start during stopper positioning
operations.
0 to 9999 (ms) 0
222 pusht2
Stopper
torque
release time
torque
release time
Set the time from the completion of the
stopper operation to the changeover of the
stopper torque during stopper positioning
operations.
stopper operation to the changeover of the
stopper torque during stopper positioning
operations.
0 to 9999 (ms) 0
223 pusht3
Set
position
signal output
delay time
delay time
Set the time from the completion of the
stopper operation to the output of the
automatic set position reached (JSTA), set
position reached (JST), and near set position
(NEAR) signals during stopper positioning
operations.
stopper operation to the output of the
automatic set position reached (JSTA), set
position reached (JST), and near set position
(NEAR) signals during stopper positioning
operations.
0 to 9999 (ms) 0