Mitsubishi Electronics E60 ユーザーズマニュアル
3. PROGRAM
ERROR
I - 77
Error No.
Details
Remedy
P610 ILLEGAL
PARA.
• The parameter setting is not correct.
• Check the program.
• Check the parameter.
• Check the parameter.
P612 EXP.
ERROR
A movement command for exponential
function interpolation was issued during
facing turret mirror image.
function interpolation was issued during
facing turret mirror image.
• Check the program.
P700 CMD-VALUE
ILL.
Spindle synchronization was
commanded to a spindle that is not
connected serially.
commanded to a spindle that is not
connected serially.
• Check the program.
• Check the parameter.
• Check the parameter.
P900
NO TANZ. SPEC
A normal line control command (G40.1,
G41.1, G42.1) was issued when the
normal line control specifications were
not provided.
G41.1, G42.1) was issued when the
normal line control specifications were
not provided.
• Check the specifications.
P901
TAN. AXIS G92
A coordinate system preset command
(G92) was issued to a normal line control
axis during normal line control.
(G92) was issued to a normal line control
axis during normal line control.
• Check the program.
P902
TAN. AXIS LINE
• The normal line control axis was set to a
• The normal line control axis was set to a
linear axis.
• The normal line control axis was set to the
linear type rotary axis II axis.
• The normal line control axis has not been
set.
• The normal line control axis was the same
as the plane selection axis.
• Correct the normal line control axis.
P903
PLANE CHG (TAN)
The plane selection command (G17,
G18, G19) was issued during normal line
control.
G18, G19) was issued during normal line
control.
• Delete the plane selection command (G17,
G18, G19) from the program for normal line
control.
control.
P990
PREPRO S/W ERR
Combining commands that required
pre-reading (nose R offset‚ corner
chamfering/corner rounding‚ geometric I‚
geometric IB‚ and fixed cycle for
compound lathe) resulted in eight or
more pre-read blocks.
pre-reading (nose R offset‚ corner
chamfering/corner rounding‚ geometric I‚
geometric IB‚ and fixed cycle for
compound lathe) resulted in eight or
more pre-read blocks.
• Reduce the number of commands that
require pre-reading or delete such
commands.
commands.