5. 
BASE SPECIFICATIONS PARAMETERS 
 
II - 24 
 
 (SETUP PARAM 1. 2/16) 
Items 
Details 
Setting range (unit) 
1025 l_plane  Initial plane 
selection 
Specify the plane to be selected when the power is 
turned ON or reset. 
When 0 is specified, 1 is assumed (X-Y plane). 
1:  X-Y plane (G17 
command state)  
2:  Z-X plane (G18 
command state)  
3:  Y-Z plane (G19 
command state) 
1026 
1027 
1028 
base_l 
base_J 
base_K 
Base axis I 
Base axis J 
Base axis K
Specify the basic axis address that composes the 
plane. 
Specify the axis address set in #1013 axname. 
If all three items do not need to be specified‚ such 
as for 2-axis specifications‚ input "0"‚ and the 
parameter will be blank. 
Normally‚ when X‚ Y and Z are specified 
respectively for base_l‚_J‚_K‚ the following relation 
will be established: 
G17: X-Y 
G18: Z-X 
G19: Y-Z 
Specify the desired address to set an axis address 
other than the above. 
Control axis addresses 
such as X, Y, and Z 
1029  aux_I 
Flat axis I 
If there is an axis parallel to #1026 base_l‚ specify 
that axis address. 
Control axis addresses 
such as X, Y, and Z 
1030  aux_J 
Flat axis J 
If there is an axis parallel to #1027 base_J‚ specify 
that axis address. 
Control axis addresses 
such as X, Y, and Z 
1031  aux_K 
Flat axis K 
If there is an axis parallel to #1028 base_K‚ specify 
that axis address. 
Control axis addresses 
such as X, Y, and Z