8. SPINDLE 
PARAMETERS 
8.1 
Spindle Base Specifications Parameters 
II - 224 
 
Items 
Details 
Setting range (Unit)
3021 sori 
Orientation 
rotation 
speed 
Set the spindle orientation rotation speed. 
Set the rotation speed for when the spindle 
rotates at the constant rotation speed. 
0 to 32767 (r/min) 
3022  sgear 
Encoder gear ratio 
Set the gear ratio of the spindle to the 
encoder. 
0: 1/1 
1: 1/2 
2: 1/4 
3: 1/8 
3023 smini 
Minimum 
rotation 
speed 
Set the minimum rotation speed of the 
spindle. 
If an S command instructs the rotation 
speed below this setting, the spindle rotates 
at the minimum rotation speed set by this 
parameter. 
0 to 32767 (r/min) 
3024 
(PR) 
sout 
Spindle connection  Set the type of the spindle to be connected. 
0: No connection with the spindle 
1: Serial connection (bus) 
2 to 5:  Analog output 
0 to 5 
3025  enc-on 
Spindle encoder 
Set connection information of the spindle 
encoder. 
0: No connection 
1: Spindle connection (Spindle encoder 
connection check function valid.)  
2: Serial connection of encoder 
0 to 2 
3026 cs_ori 
Selection 
of 
winding in 
orientation mode 
0:  Perform orientation using the winding 
selected when the orientation 
command is issued. 
1:   Use winding L whenever the orientation 
command is issued. 
0/1 
3027 cs_syn  Selection 
of 
winding in spindle 
synchronous mode 
0:  The winding H/L is selected by the 
actual spindle motor rotation speed 
(calculated from commanded rotation 
speed) when spindle synchronous 
control starts. (The winding is not 
switched during synchronous control. 
The control is carried out with the 
winding selected at start.) 
If the actual spindle motor rotation 
speed is less than SP020, the winding L 
is selected, and if more than the value, 
the winding H is selected. 
1:   Use winding H whenever the spindle 
synchronous command is issued. 
0/1 
3028  sprcmm 
L system tap cycle 
spindle forward run/ 
reverse run M 
command 
Set the M code of the spindle forward 
run/reverse run command. 
High-order three digits: 
The spindle 
forward run 
command's M 
code is set. 
Low-order three digits: 
The spindle 
reverse run 
command's M 
code is set. 
0 to 999999