Mitsubishi Electronics E68 ユーザーズマニュアル

ページ / 415
1. 
LIST OF ALARMS 
1.8 
Auxiliary Axis Alarms 
I - 40 
 
(9)  M01 AUX OPER. ALM 
Alarm 
information 
Details Cause 
Remedy 
0101 
No operation mode  The operation mode is not 
designated, or the operation 
mode was changed during axis 
movement. 
•  Correctly designate the operation 
mode. 
0103 
Feedrate 0 
The operation parameter's 
feedrate setting is zero. 
The operation parameter 
feedrate setting is zero.  
Or, the override is valid, and the 
override value is zero. 
•  Set a value other than zero in the 
feedrate setting or override value.
0160 
Station No. 
designation illegal. 
Starting not 
possible. 
A station No. exceeding the No. 
of indexed divisions was 
designated. 
•  Correctly designate the station 
No. 
0161 
Reference point 
return incomplete. 
Starting not 
possible. 
Automatic/manual operation was 
started before reference point 
return was executed with the 
incremental system. 
•  Execute the reference point 
return. 
0162 
In initializing 
reference point. 
Starting not 
possible. 
The start signal was input while 
initializing the absolute position 
reference point. 
•  Complete the absolute position 
reference point initialization. 
0163 
In absolute 
position alarm. 
Starting not 
possible. 
The start signal was input during 
an absolute position alarm. 
•  Initialize the absolute position 
reference point and then fix the 
absolute position coordinates. 
0164 
In random 
positioning mode. 
Manual operation 
not possible. 
The manual operation mode was 
started during the random 
positioning mode. 
•  Turn the random positioning 
mode OFF before switching to 
the manual operation mode. 
0165 
Uneven indexing 
station No. illegal. 
Starting not 
possible. 
The commanded station No. was 
higher than 9 or the number of 
indexing stations during uneven 
indexing. 
• Check the commanded station 
No. and the parameter "#100 
station" setting.