10 Troubleshooting
10.1 Troubleshooting procedure
105
FX
3U
-CF-ADP User's Manual
1
Introduc
tion
2
S
pecifi
cation
3
Sy
stem
 
Configurati
o
n
4
Ins
tal
lation
5
Wi
rin
g
6
Functi
o
n
s
7
Bef
o
re
 
Programm
ing
8
C
F
-AD
P
 Appl
ied 
Ins
tructi
ons
 
Explanati
o
n
9
Program 
Examples
10
T
roubl
esho
oti
n
g
805
Outside data line position range
Data cannot be written to the line position specified in the file writing
instruction.
Specify line position smaller than "Index value existing in the file +1" or
"Maximum line position specified in the file creation instruction".
806
Specified data line position not found in file
The line position specified in the file reading instruction does not exist in
the file.
Specify line position existing in the file.
807
CF file name duplication error
The file specified in the file creation instruction already exists.
Specify another file name.
808
CF file name length error
In the file creation instruction, specify the file name within 8 characters.
809
CF file name character error
The file name specified in the file creation instruction contains
unavailable characters.
Review the file name.
810
CF file time stamp error
The time stamp format specified in the file creation instruction is outside
the setting range.
Review the specified value.
811
CF file maximum line position error
The maximum line position specified in the file creation instruction is
outside the setting range.
Review the specified value.
812
CF file information number error
The maximum line position, file processing when the maximum line
position is reached or CompactFlash
TM
 card utilization of FIFO files
specified in the file creation instruction is outside the setting range.
Review the specified value.
813
File data type error
The data type specified in the file creation instruction is outside the
setting range.
Review the specified value.
815
Outside column position range
The column position specified in the file writing/reading instruction is
outside the setting range.
Review the specified value.
817
Plural data types specified in mixed type file
Data of multiple data types was attempted to be read from a file for
which a type other than mixed type is specified in the file creation
instruction.
Review the data type in the existing file, or data type to be read.
818
Outside line position range
The file specified in the file writing instruction has already reached the
maximum line position, and will not accept any more additional writing.
Delete the file, or specify another file.
900
Line search error
The specified line is not found in the file.
Check whether the file is corrupt, and whether its contents agree with
the specification.
Check whether the file contains a line larger than the maximum line
position specified in the file creation instruction.
901
File reading error
Data was not read correctly from the file.
Check whether the file is corrupt, and whether its contents agree with
the specification.
902
File writing error
Data was not written correctly to the file.
Check whether the CompactFlash
TM
 card is mounted correctly,
whether the CompactFlash
TM
 card is full, and whether the
CompactFlash
TM
 card is ready for data writing.
903
File creation error
The file was not created correctly.
Check whether the CompactFlash
TM
 card is full, and whether the
CompactFlash
TM
 card is ready for data writing.
905
File deletion error
The file was not deleted correctly.
Check whether the deletion target file is ready for deletion.
906
File opening error
The file was not open correctly. 
Check whether the CompactFlash
TM
 card is mounted correctly, and
whether the file is ready for opening.
908
FIFO file creation error
A FIFO file was not able to be created.
Check whether the CompactFlash
TM
 card is mounted correctly, and
whether the CompactFlash
TM
 card utilization specified in the file
creation instruction is exceeded.
Error 
code
Error definition
Error corrective action