Mitsubishi Electronics AJ65BT-D75P2-S3 ユーザーズマニュアル

ページ / 666
 
 
 
5 - 24 
MELSEC-A
5   DATA USED FOR POSITIONING CONTROL 
 
5.2.2 Basic parameters 2 
 
Item 
Setting value, setting range 
Default 
value 
Setting value buffer 
memory address 
Value set with peripheral 
device 
Value set with sequence 
program 
Axis 1 
Axis 2 
Pr.7  Speed limit value 
The setting value range differs depending on the " Pr.11  
Stepping motor mode selection" or " Pr.1  Unit setting". 
Here, the value within the [Table 1] range is set. 
 [Table 1] on right page
 
200000 

156 
157 
Pr.8  Acceleration time 0 
The setting value range differs according to the " Pr.25  
Size selection for acceleration/deceleration time setting". 
Here, the value within the [Table 2] range is set. 
 [Table 2] on right page
 
1000 

158 
159 
Pr.9  Deceleration time 0 
1000 
10 
11 
160 
161 
Pr.10  Bias speed at start 
The setting value range differs depending on the " Pr.11  
Stepping motor mode selection" or " Pr.1  Unit setting". 
Here, the value within the [Table 1] range is set. 
 [Table 1] on right page
 
12 
13 
162 
163 
Pr.11  Stepping motor mode 
selection 
0: Standard mode 
0 14 164 
1: Stepping motor mode 
 
 
Pr.7  Speed limit value 
 
Set the maximum speed for zero point return control and positioning control. 
The speed during positioning control must be limited according to the drive unit 
and control target. 
The speed limit conditions follow the following: 
   1) Motor speed 
   2) Workpiece movement speed 
 
 
Pr.8  Acceleration time 0,  Pr.9  Deceleration time 0 
 
Set the item to reach "
Pr.7  Speed limit value" from speed 0. 
 
Speed
Parameter speed limit value
Positioning speed
Time
Actual accel-
eration time
Actual decel-
eration time
Set acceleration time