9   MAIN POSITIONING CONTROL 
 
9.1.4 Confirming the current value 
  Values showing the current value 
 
The following two types of addresses are used as values to show the position in 
the D75P2.   
These addresses ("current feed value" and "machine feed value") are stored in the 
monitor data area, and used in monitoring the current value display, etc. 
 
Current feed value 
 This is the value stored in "RWrn + 0 to 1, RWrn + 8 to 9". 
 This value has an address established with a "machine zero point 
return" as a reference, but the address can be changed by changing 
the current value to a new value.   
 This value is updated every 56. 8ms. 
Machine feed value 
 This is the value stored in "
Md.30   Machine feed value". 
 This value always has an address established with a "machine zero 
point return" as a reference. The address cannot be changed, even if 
the current value is changed to a new value.   
 This value is updated every 56. 8ms. 
 
The "current feed value" and "machine feed value" are used in monitoring the 
current value display, etc. 
 
0
1 to
Current feed value
[RWrn+0 to 1, RWrn+8 to 9]
t
V
Zero point 
20000
Current value changed to 
20000 with the new current
value command
0
1 to
Md. 30 Machine feed value
Address after the current
value is changed is stored
10000
10000
Address does not change even
after the current value is changed
                                                       
 
Fig. 9.8 Current feed value and machine feed value