10   ADVANCED POSITIONING CONTROL 
 
10.1.1 Data required for advanced positioning control 
"Advanced positioning control" is executed by setting the required items in the "start 
block data" and "condition data", then starting that "start block data". Judgment about 
whether execution is possible, etc., is carried out at execution using the "condition 
data" designated in the "start block data".   
 
"Start block data" can be set for each No. from 7000 to 7010 (called "block Nos."), and 
up to 50 points can be set for each axis. (This data is controlled with Nos. called 
"points" to distinguish it from the positioning data. For example, the 1st start block data 
item is called the "1st point start block data" or "point No. 1 start block data".) 
 
"Condition data" can be set for each No. from 7000 to 7010 (called "block Nos."), with 
each block allowing up to 10 data to be set. 
 
The "start block data" and "condition data" are set as 1 set for each block No. 
 
The following table shows an outline of the "start block data" and "condition data" 
stored in the D75P2.   
 
Setting item 
Setting details 
Start block data
  Da.10   Shape 
Set whether to end the control after executing only the "start 
block data" of the shape itself, or continue executing the "start 
block data" set in the next point. 
Da.11   Start data No. 
Set the "positioning data No." to be executed. 
Da.12  
Special start 
command 
Set the method by which the positioning data set in  Da.11  
will be started. 
Da.13   Parameter 
Set the conditions by which the start will be executed 
according to the commands set in  Da.12 . (Designate the 
"condition data No." and "No. of repetitions".) 
 
Setting item 
Setting details 
C
ondition data
 
Da.14   Condition target 
Designate the "device", "buffer memory storage details", and 
"positioning data No." elements for which the conditions are 
set. 
Da.15   Condition operator
Set the judgment method carried out for the target set in 
Da.14 . 
Da.16
  Address 
Set the buffer memory address in which condition judgment is 
carried out (only when the details set in  Da.14  are "buffer 
memory storage details"). 
Da.17  Parameter 1 
Set the required conditions according to the details set in 
Da.14  and  Da.15 . 
Da.18
  Parameter 2 
Set the required conditions according to the details set in 
Da.14  and  Da.15 .