Mitsubishi Electronics AJ65BT-D75P2-S3 ユーザーズマニュアル

ページ / 666
 
 
 
11 - 12 
MELSEC-A
11   MANUAL CONTROL 
 
11.2.5 JOG operation example 
 When the "stop signal" is turned ON during JOG operation 
 
When the "stop signal" is turned ON during JOG operation, the JOG operation will 
stop by the "deceleration stop" method.  
JOG start signals will be ignored while the stop signal is ON.  
The operation can be started by turning the stop signal OFF, and turning the JOG 
start signal from OFF to ON again.  
 
OFF
ON
BUSY signal
OFF
ON
A JOG start signal OFF 
 ON 
while the stop signal is ON will be ignored.
Axis stop signal
OFF
ON
ON
OFF
OFF
ON
Forward run JOG start signal
D75P2 READY signal
Remote station READY signal
[RX(n+7)B]
[RXn0]
[RY(n+1)6, RY(n+1)8]
[RY(n+1)3, RY(n+1)4]
[RXn4, RXn5]
Fig. 11.6 Operation when the stop signal is turned ON during JOG operation 
 
 
POINT 
 
The D75P2 will not receive a "JOG start signal" while the "stop signal" is ON.