Mitsubishi Electronics AJ65BT-D75P2-S3 ユーザーズマニュアル

ページ / 666
 
 
 
12 - 64 
MELSEC-A
12   CONTROL AUXILIARY FUNCTIONS 
 
12.7.4 Teaching function 
POINT 
 
It is recommended to use the AD75 software package to execute this function. 
 
The "teaching function" is used to set addresses aligned using the manual control 
(JOG operation, manual pulse generator operation) in the positioning data addresses 
( Da.5
 Positioning address/movement amount,  Da.6  Arc address). 
 
The details shown below explain about the "teaching function".  
  (1) Control details 
  (2) Precautions during control 
  (3) Data used in teaching 
  (4) Teaching procedure 
 
 
(1)   Control details 
 
(a)   Teaching timing  
Teaching is executed using the sequence program when the BUSY signal 
[RXn4, RXn5] is OFF. (During manual control, teaching can be carried out 
as long as the axis is not BUSY, even when an error or warning has 
occurred.) 
 
(b)   Addresses for which teaching is possible 
The addresses for which teaching is possible are "Current feed value 
(RWrn+0 to 1, RWrn+8 to 9)" having the zero point as a reference.  The 
settings of the "movement amount" used in increment system positioning 
cannot be used. In the teaching function, these "current feed values" are 
set in the " Da.5  Positioning address/movement amount" or " Da.6  Arc 
address".  
 
  
Positioning 
data 
Positions aligned by manual 
control 
 
 
"Current feed value" A 
 
Da.5  Positioning address/movement 
amount 
 
 
 
"Current feed value" B 
 
Da.6  Arc address 
 
 
 
 
(c)   Teaching target axis (
Cd.4
 Target axis) 
Teaching can be executed for the "designated axis only" or the "2 axes 
carrying out interpolation control". When teaching is executed for the "2 
axes carrying out interpolation control", the "current feed value" is set for 
both the reference axis and the interpolation axis.