Mitsubishi Electronics AJ65BT-D75P2-S3 ユーザーズマニュアル

ページ / 666
 
 
 
3 - 10 
MELSEC-A
3   SPECIFICATIONS AND FUNCTIONS 
3.3.3 D75P2 auxiliary functions and common functions 
 Auxiliary functions  
 
The functions that assist positioning control using the D75P2 are described below. 
(Refer to "SECTION 2" for details on each function. 
 
Auxiliary function 
Details 
Reference 
section 
Functions 
characteristic 
to machine 
zero point 
return 
Zero point return retry 
function 
This function retries the machine zero point return with the 
upper/lower limit switches during machine zero point return. 
This allows machine zero point return to be carried out even if 
the axis is not returned to before the near-point dog with JOG 
operation, etc. 
12.2.1 
Zero point shift function 
After returning to the machine zero point, this function 
compensates the position by the designated distance from the 
machine zero point position and sets that position as the zero 
point address. 
12.2.2 
Functions that 
compensate 
control 
Backlash compensation 
function 
This function compensates the mechanical backlash. Feed 
pulses equivalent to the set backlash amount are output each 
time the movement direction changes. 
12.3.1 
Electronic gear function 
By setting the movement amount per pulse, this function can 
freely change the machine movement amount per commanded 
pulse. 
When the movement amount per pulse is set, a flexible 
positioning system that matches the machine system can be 
structured. 
12.3.2 
Near pass mode function 
This function suppresses the machine vibration when the 
speed changes during continuous path control in the 
interpolation control. 
12.3.3 
Functions that 
limit control 
Speed limit function 
If the command speed exceeds "
Pr.7   Speed limit value" 
during control, this function limits the commanded speed to 
within the " Pr.7   Speed limit value" setting range. 
12.4.1 
Torque limit function *
1
 
If the torque generated by the servomotor exceeds " Pr.18  
Torque limit setting value" during control, this function limits the 
generated torque to within the " Pr.18   Torque limit setting 
value" setting range. 
12.4.2 
Software stroke limit 
function  
If a command outside of the upper/lower limit stroke limit 
setting range, set in the parameters, is issued, this function will 
not execute positioning for that command. 
12.4.3 
Hardware stroke limit 
function 
This function carries out deceleration stop with the limit switch 
connected to the D75P2 external device connection connector. 
12.4.4 
Functions that 
change control 
details 
Speed change function 
This function changes the speed during positioning operation. 
This function sets a new speed to "New speed value 
(RWwm+4 to 5, RWwm+12 to 13)" and changes the speed at 
the speed change request (RY(n+2)7, RY(n+4)7). 
12.5.1 
Override function 
This function varies the speed during positioning operation at 
the ratio of 1 to 300%. "Positioning operation speed override 
(RWwm+1, RWwm+9)" is used to execute this function. 
12.5.2 
Acceleration/deceleration 
time change function 
This function changes the acceleration/deceleration time during 
speed change. 
12.5.3 
Torque change function 
This function changes the "torque limit value" during control. 
12.5.4 
Absolute position restoration function*
2
 
This function restores the absolute position of the specified 
axis. 
12.6 
 
          *
1
  To carry out "torque limit", the "D/A conversion module" and a "drive unit capable of the torque limit command with 
an analog voltage" must be prepared. 
          *
2
  The "drive unit that can configure an absolute position detection system (MR-H, MR-J2, MR-J2S)" is required to 
perform "absolute position restoration".