3.  I/O Parameters 
3.2  I/O Device Parameters 
 
11 
 
Item 
Contents 
Setting range (unit)
9107 
9207 
9307 
9407 
9507 
TERMINATOR TYPE  The code to terminate data reading can be selected.  0 and 3: EOR 
1 and 2: EOB or EOR
9108 
9208 
9308 
9408 
9508 
HAND SHAKE 
Specify the transmission control method.  
The method will be no procedure if a value except 1 
to 3 is set. 
1: RTS/CTS method 
(This method can 
be used only for 
SIO2.)  
2:  No procedure (No 
handshaking)  
3:  DC code method 
9109 
9209 
9309 
9409 
9509 
DC CODE PARITY 
Specify the DC code when the DC code method is 
selected. 
0:  No parity to DC 
code (DC3 = 13H)
1:  DC code with parity 
(DC3 = 93H) 
9111 
9211 
9311 
9411 
9511 
DC2/DC4 OUTPUT 
Specify the DC code handling when outputting data 
to the output device. 
DC2 / DC4 
0:  None / None 
1:  Yes / None 
2:  None / Yes 
3:  Yes / Yes 
9112 
9212 
9312 
9412 
9512 
CR OUTPUT 
Specify whether to insert the <CR> code just before 
the EOB (L/F) code during output. 
0:  Do not add 
1: Add 
9113 
9213 
9313 
9413 
9513 
EIA Output 
In data output mode, select the ISO or EIA code for 
data output. 
In data input mode, the ISO and EIA codes are 
identified automatically. 
0:  ISO code output 
1:  EIA code output 
9114 
9214 
9314 
9414 
9514 
FEED CHR. 
Specify the length of the tape feed to be output at 
the start and end of the data during tape output. 
0 to 999 (characters) 
9115 
9215 
9315 
9415 
9515 
PARITY V 
Specify whether to check the parity of the No. of 
characters in block during data input.  
The No. of characters is factory-set so that the 
check is valid at all times. 
0:  Do not perform 
parity V check 
1:  Perform parity V 
check