Renesas R5S72643 ユーザーズマニュアル

ページ / 2152
 
Section 21   IEBus
TM
 Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1125 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
21.3.17
  IEBus Transmit Interrupt Enable Register (IEIET) 
IEIET enables/disables interrupts for sources such as transmit start, transmit normal completion, 
and transmit error completion in IETSR. 
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
R
R/W
R/W
R
R/W
R/W
R/W
R/W
Bit:
Initial value:
R/W:
-
TXSE
TXFE
-
TXEALE
TXE 
TTMEE
TXEROE
TXE 
ACKE
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
 0 
R
Reserved 
This bit is always read as 0. The write value should 
always be 0. 
6 TXSE 0 
R/W
Transmit Start Interrupt Enable 
Enables/disables a transmit start (TXS) interrupt. 
0: Disables a transmit start (TXS) interrupt 
1: Enables a transmit start (TXS) interrupt 
5 TXFE 0 
R/W 
Transmit 
Normal 
Completion Interrupt Enable 
Enables/disables a transmit normal completion (TXF) 
interrupt. 
0: Disables a transmit normal completion (TXF) 
interrupt 
1: Enables a transmit normal completion (TXF) interrupt
 0 
Reserved 
This bit is always read as 0. The write value should 
always be 0. 
3 TXEALE 
R/W 
Arbitration Loss Interrupt Enable 
Enables/disables an arbitration loss (TXEAL) interrupt. 
0: Disables an arbitration loss (TXEAL) interrupt 
1: Enables an arbitration loss (TXEAL) interrupt