Renesas R5S72643 ユーザーズマニュアル

ページ / 2152
 
Section 25   NAND Flash Memory Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1309 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
8 STERB 
R/(W)* Status Error 
Indicates the result of status read. This bit is set to 1 if 
the specific bit in the bits STAT[7:0] in FLBSYCNT is 
set to 1 in status read. 
This bit is a flag. 1 cannot be written to this bit. Only 0 
can be written to clear the flag. 
0: Indicates that no status error occurs (the specific bit 
in the bits STAT[7:0] in FLBSYCNT is 0.) 
1: Indicates that a status error occurs 
For details on the specific bit in STAT7 to STAT0 bits, 
see section 25.4.7, Status Read. 
7 BTOERB 
R/(W)* R/
B Timeout Error 
This bit is set to 1 if an R/
B timeout error occurs (the 
bits RBTIMCNT[19:0] in FLBSYCNT are decremented 
to 0). 
This bit is a flag. 1 cannot be written to this bit. Only 0 
can be written to clear the flag. 
0: Indicates that no R/
B timeout error occurs 
1: Indicates that an R/
B timeout error occurs 
6 TRREQF1 
R/(W)* FLECFIFO Transfer Request Flag 
Indicates that a transfer request is issued from 
FLECFIFO. 
This bit is a flag. 1 cannot be written to this bit. Only 0 
can be written to clear the flag. 
0: Indicates that no transfer request is issued from 
FLECFIFO 
1: Indicates that a transfer request is issued from 
FLECFIFO