Mounting the Unit 
Rugged Dome Installation Manual 
 
12 
1038346B / February 2003 
Note: Ensure that you trace the back of the outer plate: this is the side with the 
smaller diameter. If you trace the diameter of the front of the plate, your mounting 
hole will be too large. 
3)  Trace the outline of the back of the outer plate onto the ceiling 
panel. 
4)  Use the traced outline as a guide to cut out the mounting hole. 
To install the back and outer plates perform the following. 
1)  From the inside of the back plate, insert the three M5x20 pan-head 
double-washer screws into the three holes.  
Note: The screws should be secure but they should not protrude out the back of the 
plate. 
2)  Set the back plate onto the back of the ceiling panel and center it 
over the mounting hole.  
3)  Slide the outer plate into the mounting hole and back plate. 
4)  Line up the mounting holes and slots in the outer plate with the 
three M5x20 pan-head double-washer screws in the back plate. 
5)  Slide the outer plate onto the screws in the back plate. 
6)  Rotate the outer plate counterclockwise to secure it to the back 
plate.  
To install the housing perform the following. 
1)  Let the housing cover drop down and rest on the hinge. 
2)  Attach the housing to the inner plate using the M4x12 pan-head 
double-washer screws. 
3)  Slide the back of the housing and attached inner plate into the 
outer plate. 
4)  Rotate the housing counterclockwise to slide the mounting slots on 
the inner plate onto the screws in the back plate. 
To make remaining cable connections, see section 3.