Mitsubishi Electronics MDS-D-SVJ3 ユーザーズマニュアル

ページ / 284
Appendix 3 - 4
Appendix 3 Compliance to EC Directives
MITSUBISHI CNC
(6) Peripheral devices
[1] Use EN/IEC Standards compliant parts for the circuit protector and contactor.
[2] Select type B circuit protector manufactured by RCD.
 Apply Annex C of EN60204-1 for sizing of the circuit protector.
(7) Miscellaneous
[1] Refer to the next section "EMC Installation Guidelines" for methods on complying with the EMC 
Directives.
[2] Ground the facility according to each country's requirements.
[3] The control circuit connector (
○) is safely separated from the main circuit (
) and ground (
●).
[4] Inspect the appearance before installing the unit. Carry out a performance inspection of the final unit, 
and save the inspection records.
 
OPT1,2 
CN1A
 
CN9
 
CN1B
 
CN2
 
PLG
 
CN3
 
CN1A
 
CN9
 
CN1B
 
CN2
 
CN3
 
L1 
L2 
L3 
L11 
L21 
L1 
L2 
L3 
L11 
L21 
CNP2
 
CNP1
 
CNP2
 
CNP3
 
CNP2
 
CNP1
 
CNP2
 
CNP3
 
D
:Main circuit
:Control circuit
Mitsubishi CNC
Servo drive unit
Ground
Motor side
detector
 
 
Spindle drive unit
Ground
Machine side
detector
Optical communication cable
Optical communication
cable
Regenerative
resistor unit
 
Spindle
motor  
 
Servo
motor
Circuit
protector
 Contactor
Spindle side
detector
Contactor
Circuit
protector
Circuit
protector
Circuit
protector
Regenerative
resistor unit
When using a built-in 
regenerative resistor, 
use a shorted wire.
:Ground