Impinger I – Adv Digital – Gas Service Manual – International 
SEQUENCE OF OPERATION 
IMPINGER ADVANTAGE 
SERIAL NUMBER N28654 AND ABOVE 
(OVENS WITH PUSH BUTTON CONTROLS) 
 
 
   MODEL 
1433-000-E 
230VAC 50 
HZ. 
 NAT. 
GAS 
   MODEL 
1434-000-E 
230VAC 50 
HZ. 
 LP 
GAS 
   MODEL 
1456 
 220/240VAC 
50 
HZ. 
 NAT. 
GAS 
   MODEL 
1457 
 220/240VAC 
50 
HZ. 
 LP 
GAS 
 
POWER SUPPLY 
Electrical power is to be supplied to the oven by a three conductor 
service. 
Brown conductor is hot. 
Blue conductor is neutral. 
Green conductor is ground. 
CONTROL BOX AUTO 
COOL DOWN 
When the temperature in the control box reaches 120
°F ± 3°F (48.9°C 
± 1.7°C), the cooling fan thermostat will switch power to the control 
box cooling fan. The thermostat will interrupt power to the cooling fan 
when the control box temperature falls to 100
°F ± 3°F (37°C ± 1.7°C). 
MAIN FAN CIRCUIT 
Electrical power is permanently supplied, through the 10 Amp oven 
fuse, to a normally open contact of the oven power switch. Power is 
also supplied to the control box cooling fan. Closing the oven power 
switch supplies line voltage to the main fan motor. Closing the oven 
power switch also supplies line voltage to the heat circuit and to the 
primary of the oven control transformer. 
BURNER CIRCUIT  
Closing the oven power switch supplies line voltage through the main 
fan air pressure switch, through the normally closed oven cavity hi-limit 
thermostat. Through the gas pressure proving switch (gas pressure 
switch removed at S/N N31348) to the ignition control. The combustion 
motor is now energized, the normally open combustion air switch 
closes upon sensing air. After a pre-purge period between 30 and 60 
seconds, the spark generator and the main gas valve are energized. 
Ignition should now occur  
TEMPERATURE CONTROL 
Closing the oven fan switch supplies line voltage to the primary of the  
control transformer and through the ignition control, to the oven 
control. Secondary voltage, 24VAC, is supplied to the oven control. 
The oven control is set to desired temperature. The thermocouple will 
provide varying millivolts to the oven control. The oven control supplies 
line voltage to the temperature regulation valve at intermittent intervals 
to maintain desired temperature. The display on the oven control will 
indicate when the temperature regulation valve is energized. 
NOTE: The display also indicates oven temperature. 
CONVEYOR DRIVE 
Closing the oven power switch supplies line voltage to the conveyor 
motor and to the primary of the control transformer. Secondary 
voltage, 24VAC, is supplied to the oven control. Setting the oven 
control to the desired time outputs voltage, through a reversing switch, 
to the conveyor motor. 
NOTE: The conveyor system uses a hall effect sensor and magnet to 
prove operation of the conveyor motor. If the motor is not running, 
“BELT JAM” is indicated on the display.