LED Status 
Control Status 
Probable Cause 
Service Procedure 
Eight flashes, 
three flashes, 
three second
pause
Thermal well sensor 
damaged or un-
plugged or gas con-
trol electronics fault
detected 
1. Damage to thermal well wires 
2. Thermal well sensor resistance 
out of range 
3. Replace thermal well
4. Verify control is not wet or 
physically damaged 
5. Reset control on/off switch 
6. Replace gas control if 8-3 error 
persists 
See Thermal Well Testing on 
page 34
Eight flashes, 
four flashes, 
three second
pause
Gas control fault
detected 
1. Verify control is not wet or 
physically damaged 
2. Reset control on/off switch 
3. Replace gas control if 8-4 error 
persists 
1. Replace gas control if wet 
or physically damaged
2. Cycle power 
3. Replace gas control
Troubleshooting