Step 6. 
Remove the connectors attached to the re-
settable thermal switch on the manifold mount. 
Inner Door Removal Procedure (cont’d)
Step 7. 
Remove the flammable vapor sensor from the clip by 
pushing down on the tab to open the clip.
Step 8. 
Inspect both inner doors for any of the following imperfections: tears,
missing material, cracks, dirt or debris, lack of adhesion to the inner door, material left 
on combustion chamber, or any other imperfections that will inhibit a proper seal. 
If any of the imperfections above are present, 
replace  the  inner 
door gasket following the Inner Door Gasket 
Replacement Procedure.  If not, replacement 
of the inner door gaskets is not necessary. 
Inner Door Gasket Replacement Procedure 
Step 1. 
Completely remove all gasket and adhesive 
residue from the right and left side inner doors, as needed. 
Step 2. 
U s i n g 
RTV sealant, 
apply a 1/8” 
bead to secure 
t h e
Inner Door Gasket Replacement 
Flammable vapor 
sensor
Flammable vapor 
sensor clip
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, 
personal injury, or death. 
Recommended pattern for RTV sealant 
Expanded view 
Slice gasket here to slide over burner venturi
Gasket overlap must be 
as shown ± 1/32 
Enlarged
view of
flange
area
Gasket overlap must be 
as shown ± 1/32 
47