3com 3012 (3C13612) ユーザーズマニュアル
50
C
HAPTER
5: T
ROUBLESHOOTING
Illegible Characters
Display on the
Terminal after
Power-On
Display on the
Terminal after
Power-On
If the system operates normally after the system runs the POST, the start-up
information is displayed on the console terminal. If the configuration system has a
fault, the terminal may display only illegible characters.
information is displayed on the console terminal. If the configuration system has a
fault, the terminal may display only illegible characters.
If the console terminal displays illegible characters after the POST, verify that the
HyperTerminal parameters are set properly, as follows:
HyperTerminal parameters are set properly, as follows:
■
Baud: 9600
■
Data bits: 8
■
Stop bit: 1
■
Parity: None
■
Flow control: None
■
Terminal emulation: VT100
If the parameter settings do not match these values, reconfigure them.