MAINTENANCE
FAN MAINTENANCE
If your fan requires maintenance or replacement, 
access to the fan is through the plate on the rear 
wall of the fi rebox.  NOTE: the unit MUST NOT 
be operated without the fan access panel 
securely in place and correctly sealed.
IMPORTANT: These fans collect a lot of 
dust from within your home. Ensure 
you maintain these fan motors on a 
regular basis by vacuuming out the 
fan squirrel cages, around the motor, 
and around the grills on the back of 
the stove.
Alternate Fan Access:
If the rear access cover is 
accessible, it can be removed to 
provide access to the fan.
IMPORTANT
Disconnect power supply 
before servicing
WARNING: 
Electrical Grounding 
Instructions
This appliance is equipped with 
a three pronged (grounding) plug 
for your protection against shock 
hazard and should be plugged 
directly into a properly grounded 
three-prong receptacle. Do not cut 
or remove the grounding prong 
from this plug.
7)  Tighten side panels nuts using the following 
procedure:
 
a.  tighten top & bottom outside corner nuts 
(2)
 
b.  tighten inside nuts (3) 
 
c.  tighten top & bottom inside corners (2)
8)  Tighten the 10 nuts on center glass 
retainer.
9)  Repeat step 7 for other side panel.
10) Replace new gasket by gluing it in place.
11) Install door onto stove and check the seal.
To Remove U39 Fan:
1)  Unplug or disconnect power source to 
stove.
2)   Remove all logs and the rear log support, 
then remove the 10 screws holding the 
access panel in place.
3)  Unclip the black and white wires from the 
fan motor.
4)   Open both side doors and gently pull the 
fl ex pipe away from the center, otherwise 
the fan can catch on the fl ex pipe during 
installation and tear the pipe. Do not tear 
or damage the fl ex pipe.
5)  Lift fan off of the 2 pins, tip back and pull 
through fi rebox opening. Disconnect the 
green ground wire from the right side of the 
fan as soon as you can reach it.
Replacing U39 Fan:
Reverse the above steps (1 - 5). If necessary 
install a new gasket before replacing the fan 
access panel.  Make sure the fan wires and the 
ground wire are reattached.  
Hint for pushing fan down onto pins - rub a 
bit of dish soap on the grommet so it will slide 
more easily onto the pin. Check to make sure 
the fan is seated properly on the pins - try to 
move the fan back and forth, there should be 
no noise, if there is check that the grommets 
haven't come loose.
DC SPARKER BATTERY
REPLACEMENT
The battery in the DC Spark box needs to be 
replaced annually.
1)  Remove the DC Spark box from the back 
of the pedestal cover by removing the heat 
shield. 
2)  Remove the Heat Shield from the DC 
Spark Box. 
3)  Place 1 AA battery into the DC Spark Box 
by opening the battery compartment.
4)  Reverse steps to put back in place.